End position setting
Installation Method 3: Fixed upper and lower stop
Installation Method 3: Fixed upper und lower limit stops
Note: Ensure that the equipment is correctly connected.
STOP
1. Move the blind up to approx. 5 cm before the upper limit stop.
The drive starts up slowly with a short STOP.
STOP
2. Press the UP momentary contact switch again.
Approach the upper limit stop.
The drive switches off automatically when it reaches the limit
stop.
STOP
3. Press the DOWN momentary contact switch until the drive
stops automatically.
The upper limit stop is programmed.
STOP
4. Press the DOWN momentary contact switch again.
Run the blind until shortly before the lower limit stop.
The drive starts up slowly with a short STOP.
STOP
5. Approach the lower limit stop.
The drive switches off automatically when it reaches the limit
stop.
STOP
6. Press the UP momentary contact switch until the drive stops
automatically.
The lower limit has been set.
Setting of the end positions is now complete.