ProLights ECLIPSEFS User Manual
ProLights ECLIPSEFS User Manual

ProLights ECLIPSEFS User Manual

Led profiler

Advertisement

ECLIPSEFS
LED PROFILER
ECLIPSEFS
OPTIC
14° / 19° / 26° / 36° / 50°
USER MANUAL
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECLIPSEFS and is the answer not in the manual?

Questions and answers

Summary of Contents for ProLights ECLIPSEFS

  • Page 1 ECLIPSEFS LED PROFILER ECLIPSEFS OPTIC 14° / 19° / 26° / 36° / 50° USER MANUAL...
  • Page 2 In order to improve the quality of products, PROLIGHTS reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.
  • Page 3: Table Of Contents

    4. 1 Maintenance and cleaning the unit 4. 1 Maintenance and cleaning the unit 4. 2 Fuse replacement 4. 2 Fuse replacement 4. 3 Trouble shooting 4. 3 Trouble shooting • ECLIPSEFS Packing content • Power cable • User manual...
  • Page 4: General Instructions

    ECLIPSEFS WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with cure for future reference. It contains important information about the installation, usage and maintenance of the unit. SAFETY General instruction • The products referred to in this manual conform to the European Community Directives and are there- fore marked with and approved for the North American Market.
  • Page 5: Introduction

    ECLIPSEFS - 1 - INTRODUCTION 1.1 TECHNICAL DRAWING ECLIPSEFS + OPTIC 268.8mm/ 663.3mm/26,11in 10,58in Technical drawing Fig.1...
  • Page 6: Configurations

    ECLIPSEFS 1.2 CONFIGURATIONS Configuration Middle part, compatible with Reflector Housing 14°, 19°, 26°, 36°, 50° optics ECLIPSEFS Optics for ECLIPSE profiler, Optics for ECLIPSE profiler, 14° beam 19° beam Optics for ECLIPSE profiler, Optics for ECLIPSE profiler, 26° beam 36° beam Optics for ECLIPSE profiler, 50°...
  • Page 7: Operating Elements And Connections

    2. LOCKING KNOB for the mounting bracket used to access the control panel functions 3. HANDLE and manage them. 4. ECLIPSEFS 12. POWER OUT (PowerCON OUT): connect to 5. SAFETY EYE to attach safety cable. supply power to the next unit.
  • Page 8: Installation

    2.1 MOUNTING ECLIPSEFS may be set up on a solid and even surface. The unit can also be mounted upside down to a cross arm. For fixing, stable mounting clips are required. The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight.
  • Page 9: Functions And Settings

    ECLIPSEFS - 3 - FUNCTIONS AND SETTINGS 3.1 OPERATION Connect the supplied main cable to a socket (100-240 VAC-50/60 Hz). Then the unit is ready for operation and can be operated via a DMX controller or it independently performs its show program in succession.
  • Page 10: Menu Structure

    ECLIPSEFS 3.3 MENU STRUCTURE MENU CONNECT ð ð DMX Address Value (1-512) Default: 5CHRGBL DMX Mode ð 3CHRGB 4CHRGBL 5CHRGBL 13CH Tungsten (Define by Static=>Tungsten) 1CH-3200K 1CH-5400K 1CH-6500K RDM ID ð Name EclipseFS ð RDM Mode Mode1/Mode2 Default: Mode1 050 (end user calibration)
  • Page 11 ECLIPSEFS INFORMATION ð XXXX(Hours) Time Info. Current XXXX(Hours) Temperature Fixture Life Factory Cal Near Lamp Temp Factory RDM Software Ver 1U01 V1.0.00 STATIC ð ð Play DMX Receive Slave Receive ð Master / Alone / DMX Presets ð Master / Alone / DMX...
  • Page 12 ECLIPSEFS DEFAULT ð ð Basic Reload On/Off ð Program Reload On/Off Password Private Reload ð On/Off Recover calibration and RDM PID code All Reload ð On/Off Recover calibration and RDM PID code...
  • Page 13: Static Mode

    • Select the desired DMX configuration (1CH - - 2CH - 3CH - 3CHRGB - 4CH RGBL- 5CH - 5CHRGBL - 8CH - 13CH - 1CH 3200K - 1CH 5400K - 1CH 6500K) through the buttons UP/DOWN. The tables on page 13 indicate the operating mode and DMX value. The ECLIPSEFS is equipped with 5-pole XLR connections.
  • Page 14: Fixture Id And Rdm

    ECLIPSEFS automatically assigned to the following addresses. An example with the start address 33 is shown below: Number of Start address DMX Address Next possible start Next possible start Next possible start DMX channels (example) occupied address for unit No. 1 address for unit No.
  • Page 15: Connection Of The Dmx Line

    ECLIPSEFS 3.9 CONNECTION OF THE DMX LINE DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω imped- ance and low capacity. The following diagram shows the connection mode: DMX - INPUT DMX - OUTPUT XLR plug XLR socket...
  • Page 16: Dmx Control

    ECLIPSEFS 3.11 DMX CONTROL Channel FUNCTION Value Tun 3200K 5400K 6500K 1CH 8CH 13CH RGBL RGBL Dimmer Dimmer(Close to Open) 000 - 255 Dimmer fine Dimmer fine 0->100% 000 - 255 CTC Preset 2000K 000 - 022 2000K->2700K 023 - 057 2700K->3200K...
  • Page 17: Setup

    ECLIPSEFS 3.12 SETUP You can change the parameters for the device by following these steps: Temperature Through the Max Temperature function can be displayed the temperature inside the fixture, near the lamp. • Press the MODE button so many times until the display shows SETUP, then press the button ENTER.
  • Page 18: Fixure Information

    ECLIPSEFS • Press the button UP/DOWN to select Dimmer1 - Dimmer2 - Dimmer3 - Dimmer4. • Press ENTER button to store. • Press the MODE button to go back or to meet the waiting time to exit the setup menu.
  • Page 19: Maintenance

    ECLIPSEFS - 4 - MAINTENANCE 4.1 MAINTENANCE AND CLEANING THE UNIT • Make sure the area below the installation place is free from unwanted persons during setup. • Switch off the unit, unplug the main cable and wait until the unit has cooled down.

Table of Contents