Set Option - Zapi DUALACE2 NEW GENERATION User Manual

Table of Contents

Advertisement

Parameter
P THROTTLE X1 MAP
(C)
P THROTTLE Y1 MAP
(C)
P THROTTLE X2 MAP
(C)
P THROTTLE Y2 MAP
(C)
P THROTTLE X3 MAP
(C)
P THROTTLE Y3 MAP
(C)

8.2.4 Set Option

Parameter
HM DISPLAY OPT.
(D, C)
HM CUSTOM 1 OPT.
(A)
HM CUSTOM 2 OPT.
(A)
AFNZPxxx– DUALACE2 NEW GENERATION – User Manual
PARAMETER PUMP
Allowable range
0% ÷ 100%
(steps of 1%)
0% ÷ 100%
(steps of 1%)
0% ÷ 100%
(steps of 1%)
0% ÷ 100%
(steps of 1%)
0% ÷ 100%
(steps of 1%)
0% ÷ 100%
(steps of 1%)
SET OPTIONS
Allowable range
0 ÷ 6
0 ÷ 6
0 ÷ 6
Description
This parameter defines the lift potentiometer curve.
See paragraph 9.9.
This parameter defines the lift potentiometer curve.
See paragraph 9.9.
This parameter defines the lift potentiometer curve.
See paragraph 9.9.
This parameter defines the lift potentiometer curve.
See paragraph 9.9.
This parameter defines the lift potentiometer curve.
See paragraph 9.9.
This parameter defines lift potentiometer curve.
See paragraph 9.9.
Description
This parameter defines the configuration for the hour meter
shown on a display (i.e. MDI). The possible settings are the
same described for parameter HM CUSTOM 1 OPT..
This parameter decides the configuration for the hour meter
number 1 accessible to the customer.
The possible settings are:
0: The hour meter counts since the controller is on.
1: The hour meter counts when the three-phase
power bridge is active.
2: Not used in ACE2 NEW GENERATION.
3: The hour meter counts when one of the valve
outputs is active.
4: Not used in ACE2 NEW GENERATION.
5: The hour meter counts when one of the valve
outputs is active.
6: Not used in ACE2 NEW GENERATION.
This parameter decides the configuration for the hour meter
number 2 accessible to the customer. The possible settings
are the same of HM CUSTOM 1 OPT. parameter.
Page 77/169