GO Regulator HPR-2 Wiring Instructions

GO Regulator HPR-2 Wiring Instructions

Electrically heated vaporizing regulators for tco and non-tco types

Advertisement

HPR-2 & HPR-2XW Electrically Heated Vaporizing Regulator
Wiring Instructions for TCO and non-TCO types
Make sure you thoroughly understand these directions before proceeding
MAKE SURE THE REGULATOR IS DISCONNECTED FROM PRESSURE SOURCE
MAKE SURE ANY RESIDUAL PRESSURE IS BLED OFF FROM REGULATOR.
D
isassembly
1.
Make sure the regulator is disconnected from pressure source; make sure any residual pressure is bled off from
FAILURE TO DO THIS WILL RESULT IN SERIOUS PERSONAL INJURY. DO NOT PROCEED UNTIL
the regulator.
PRESSURE HAS BEEN REMOVED AND/OR TERMINATED
2.
Disconnect unit from AC power supply or terminate AC power supply at its source.
RESULT IN SERIOUS PERSONAL INJURY. DO NOT PROCEED UNTIL AC POWER HAS BEEN REMOVED AND/OR
TERMINATED.
3.
Unscrew condulet cap. If the condulet cap is equipped with a locking set screw, this must be loosened prior to
unscrewing condulet cap.
4.
Loosen and remove the screws that hold the AC feed wires. Carefully remove the AC feed wires and any conduit
that is attached to the condulet. This leg of the condulet must be open to be able to remove the thermistor/heater

assembly.

5.
Loosen the standoffs with a socket. Loosen the screws at position 1 and 3 on the terminal strip and remove the
controller.
6.
Remove the two outside screws that hold the terminal strip onto the sub-plate. Remove the terminal strip.
7.
Loosen and remove the two screws that hold the sub-plate onto the condulet. Remove the sub-plate.
8.
Carefully feed the wires of the thermistor/heater assembly through the hole on the opposite side of the condulet.
Continue pulling on the wires, gradually increasing the load just until the thermistor/heater assembly breaks loose.
Feed the loose thermistor/heater assembly all the way through the hole in the condulet.
FAILURE TO DO THIS WILL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPR-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for GO Regulator HPR-2

  • Page 1 HPR-2 & HPR-2XW Electrically Heated Vaporizing Regulator Wiring Instructions for TCO and non-TCO types Make sure you thoroughly understand these directions before proceeding MAKE SURE THE REGULATOR IS DISCONNECTED FROM PRESSURE SOURCE MAKE SURE ANY RESIDUAL PRESSURE IS BLED OFF FROM REGULATOR.
  • Page 2 Connect the ground wire to either the internal GREEN grounding screw, or to the external GREEN grounding screw. Failure to properly ground this unit will pose a safety hazard. Screw down the condulet cap and tighten. GO Regulator 405 Centura Court • PO Box 4866 • Spartanburg, SC 29303 Phone (864) 574-7966 • Fax (864) 574-5608...

This manual is also suitable for:

Hpr-2xw

Table of Contents

Save PDF