14
Certificate
Growatt SPH series inverter apply within the scope of the world, So the inverter have
to satisfy different countries and regions of different safety standards.
Model
Growatt SPH3000TL BL-UP
Growatt SPH3600TL BL-UP
Growatt SPH4000TL BL-UP
NRS 097-2-1
Growatt SPH4600TL BL-UP
Growatt SPH5000TL BL-UP
Growatt SPH6000TL BL-UP
15
Contact
If you have technical problems about our products, contact the Growatt Service line
or dealer. We need the following information in order to provide you with the
necessary assistance:
1. SPH inverter Serial number
2. SPH inverter module information
3. SPH inverter communication mode
4. SPH inverter fault information code
5. SPH inverter Display content
6. The manufacturer and model of the battery
7. Battery capacity and connection mode
Shenzhen Growatt New Energy Technology Co.,LTD
No.28 Guangming Road, Shiyan Street, Bao'an District, Shenzhen, PR.China
T: +86 0755 2951 5888
E: service@ginverter.com
W: www.ginverter.com
63
Certificate
Auto Test (only for Italy)
Follow is the chart of Auto Test, refer to 6.4.4. in the set up surface of "Auto Test".
Press the "Enter" key, make sure to start auto test by press "enter" key 3 seconds.
The LCD will display the follow message.
WorkMode
WorkMode
Auto Test
YES ?
Press "enter"more
than 3 seconds to enter
Annex
59.S2
Limit
Waiting to start
59.S1
Limit
253.0V 3000ms
59.S2
Limit
264.5 V 200ms
59.S1
Testing
230.4- xxxxV
59.S2
Testing
230.8 V - xxx V
59.S1
Pass
254.7V 3000ms
59.S2 Pass
264.7 V
180ms
27.S2
Limit
92.0V 200ms
27.S1
Limit
195.5 V 400ms
27.S2 Testing
230.4- xxxxV
59.S2
Testing
230.8 V - xxx V
27.S2
Pass
59.S2 Pass
90.8V 180ms
194.7 V
380ms
81>S1
Limit
81>S2
Limit
50.5HZ 100ms
51.5HZ 100ms
81>S1 Testing
81>S2
Testing
50.01- xxxxHZ
50.01-xxxxHz
81>S1 Pass
81>S2
Pass
50.05V 80ms
51.52HZ 80ms
81<S1
Limit
49.5HZ 100ms
81<S2
Limit
47.50HZ 100ms
81<S1 Testing
50.01- xxxxHZ
81<S2
Testing
50.01-xxxxHz
81<S1 Pass
49.5HZ 80ms
81<S2
Pass
47.49HZ 80ms
Auto Testing
Auto Test Passed