CHECK ENTRY STATUS 1 AND 2 CHECK LAST CALL 06. USE AS ALARM This marking indicates that the product and electronic CONFIGURE M175 AS ALARM COMMUNICATOR CONFIGURE THROUGH SMS accessories (eg. charger, USB cable, electronic material, 07. ACCESS RECORD controls, etc.) are susceptible to electric shock by direct or REGISTER WITH microSD (OPTIONAL) indirect contact with electricity.
01. SAFETY INSTRUCTIONS GENERAL WARNINGS the motorized door or gate from being triggered involuntarily. • This manual contains very important safety and usage information. WARNINGS FOR TECHNICIANS very important. Read all instructions carefully before beginning the installation/usage procedures and keep this manual in a safe place •...
Page 4
01. SAFETY INSTRUCTIONS RESPONSABILITY to the release mechanism. • Disconnect means, such as a switch or circuit breaker on the electrical • Supplier disclaims any liability if: panel, must be provided on the product’s fixed power supply leads in • Product failure or deformation result from improper installation accordance with the installation rules.
DEVICE FUNCTIONS TECHNICAL CHARACTERISTICS • Control of two outputs independently or interconnected. The M175 device has been designed to control remotely equipment (via GSM) via phone call • Device status monitoring via two inputs. and SMS, or via Bluetooth connection.
02. THE DEVICE VISUAL ASPECT LED POW Without power With power LED ACT Blinks once Normal operation 1st pulse Antenna sequence Blinks 2 times With active bluetooth user Pause of 1 second Blinks once Network signal Excellent MicroSIM Slot Blinks 2 times Network signal Good 2nd pulse sequence...
At the outputs, you must connect devices that you At the inputs, you must connect devices on which want to control with the M175: you want to be informed of state changes, such as: ex: garage door and service door...
04. PRE-CONFIGURATION 04. PRE-CONFIGURATION ACCESS PASSWORDS SETTINGS LEGEND Only those who have Administrator password are allowed to make settings on the GSM M175 ELEMENTS DESCRIPTION via SMS / Bluetooth. Setting up general functions • The default administrator password is 9999.
RESPONSE SMS FORMAT RESTORE SETTINGS The M175 makes it possible to return an SMS indicating the result of the operation you have performed. The return message is displayed as follows. · Example: Respond to a change of the administrator password.
This setting allows automatic synchronization of the date and time. be correct. · This allows the M175 to send a message every 3 months so that the mobile operator This update can be done manually with the instructions in this menu, or automatically does not disable the card and send a message in case of restarting the M175 to when the CONFIGURE SIM CARD NUMBER menu is set (see page 10A).
RECOVER ADMINISTRATOR PASSWORD SET UP BLUETOOTH PAIRING TYPE Each M175 has a code (15 digits) that allows to reset the Administrator password in Two Bluetooth pairing modes are available with the device. · Permanent mode (0): GSM stores up to 10 paired Bluetooth devices, not allowing the case of oversight.
Is possible set the days of the week that users can or cannot activate relay output 1. setting defines the daily interval of time that the user is authorized to make calls to This configuration value has 7 digits and each corresponds to a day of the week (from the M175. Sunday). 0: Day without permission...
SET UP USER SET UP USER The M175 detects whether the value to be changed is Time, Days of the Week or Password by The M175 allows you to add users for activation of Relay 1 or Relay 2. the number of digits of the value entered in SMS: After the user is added, it is only necessary to make a phone Call so that Relay 1 ·...
Page 14
MOTORLINE R1 G R (0/1) Check RELAY status 2 1234 R2.G.R 91XXXXXXX MOTORLINE R2 G R (0/1) The M175 has two relay outputs with normally open contact (NO). Relay Output 1 and Relay Output 2. Start RELAY 1 1234 R1.S.R 91XXXXXXX MOTORLINE R1 S R 1 Relay 1 can be activated by phone call / Bluetooth and SMS.
(in these functions you shoulde put "?" at the end of the message you send if you want to receive a reply) The M175 allows you to set up to four phone contacts so that feedback notifications (SMS) can be sent on unrequest events.
MOTORLINE I2 G I (0/1) Relay 1 is activated ENTRY 2 MOTORLINE OUT2 Relay 2 is activated CHECK LAST CALL Example: Is possible verify the last number who cal for the M175. IN1(NC) IN1(NO) IN2(NC) IN2(NO) Function Send Message Device Response Check Last Calls 9999 ME.G.L...
06. USE AS ALARM CONFIGURE M175 AS ALARM COMMUNICATOR CONFIGURE THROUGH SMS It is possible to configure the M175 to function as an alarm communicator. When activated, it makes a call to the configured numbers (max. 4). 9 9 9 9 F 1 .
1 964685641 R1 "19/04/29,10:10:35+00" 91XXXXXXXBT User by bluetooth COLUMN 3 RELAY INFO Relay 1 Sheet "access.txt" Relay 2 Operation failed COLUMN4 DATE AND TIME To enable this feature, insert a microSD card into the corresponding slot on the M175. "00/00/00,00:00:00+00" Relay 1...
08. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS INSTRUCTIONS FOR SPECIALISED TECHNICIANS Anomaly Procedure Behavior Discovering the origin of the problem Try to add the number again. Check if: 1 • The number consists only of digits (without any space or other character). It does not 2 •...
Need help?
Do you have a question about the M175 and is the answer not in the manual?
Questions and answers