Cable storage | Stage 3
Attention: Be sure to check the illustration arrow for the proper cable connector pull-tab orientation.
Note:
To unplug a cable, gently pull the tab to release the locking mechanism.
Cabling an AFF A400 system
to one NS224 shelf
100 GbE QSFP28 copper cable
Connect controller A port e0c
to port e0a on NSM A on the shelf.
Connect controller A port e0d
to port e0b on NSM B on the shelf.
Connect controller B port e0c
to port e0a on NSM B on the shelf.
Connect controller B port e0d
to port e0b on NSM A on the shelf.
Cabling an AFF A400 system
to two NS224 shelves
100 GbE QSFP28 copper cable
Use the table below to connect your
controllers to the two NS224 shelves.
e0c
e0d
Controller A
1
2
e0c
e0d
Controller B
1
2
NSM A
NSM B
Controller A
Controller B
NSM A
NSM B
Shelf 1
e0a
NSM A
Controller A
e0b
e0a
NSM B
e0b
Shelf 2
e0a
Controller B
NSM A
e0b
e0a
NSM B
e0b
NSM A
NSM B
e0a
e0a
1
2
3
1
2
3
e0a
e0a
1
2
3
1
2
3
e0a
e0a
Pull-tab
Shelf 1
e0b
e0b
4
5
e0c
e0d
4
5
e0c
e0d
Shelf 1
e0b
e0b
4
5
2
1
e0c
e0d
4
5
2
1
e0c
e0d
e0b
e0b
Shelf 2
Need help?
Do you have a question about the AFF A400 and is the answer not in the manual?
Questions and answers