Serial connection to a Lantime
without a Display - LANTIME V5 Firmware
In the LANTIME NTP server without a display one has to start
a serial connection between a PC and the LANTIME in order
to check or assign a Lantime IP address. The serial connection
can be set up with a NULL-MODEM cable or via an USB to
Serial Adapter.
1. Open an SSH client on your PC (e.g. PuTTy.exe). Type in
the serial port of the PC and the connection values for
speed and framing, for our example 38400 Baud / 8N1 as
shown in Fig. 1. Confirm with Open button.
Figure 1: Serial connection with an SSH client.
2. LOGIN with a Username and a Password-
Default values root / timeserver.
3. Type in setup to enter the Lantime Configuration window.
4. Choose Ethernet menu (in the lower left corner) and
confirm with „Enter" to enter the Ethernet Configuration
window. Secondly, choose Ethernet 0 to proceed to the
Ethernet Configuration Line 0 as shown in Fig. 2.
Figure 2: Ethernet Configuration Line, where the Lantime
IP address is configured .
5. Note down the IP address and Netmask as assigned from
a DHCP.
MEINBERG Radio Clocks - www.meinberg.de
2013-07
Page 1
Serial connection setup
The figure shows a LANTIME M100 connected with
power, network, GPS antenna and a serial connection
between a LANTIME and a computer.
2
USB to Serial Adapter
1
If you do not use a NULL-MODEM cable you have to connect
a signal changer (TxD - RxD)
the used adapter cable is equipped with an male connector
6. Close this window and exit the SSH client.
7. Connect the LANTIME with your network and start
the WEB interface in your browser via the configured
IP-Address.
1
3
and a gender changer
2
if
3

Advertisement

loading
Need help?

Need help?

Do you have a question about the LANTIME Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Meinberg LANTIME Series

  • Page 1 7. Connect the LANTIME with your network and start 5. Note down the IP address and Netmask as assigned from the WEB interface in your browser via the configured a DHCP. IP-Address. MEINBERG Radio Clocks - www.meinberg.de 2013-07 Page 1...
  • Page 2 9. Apply the new configuration with the command IPV4-NETMASK=xxx.xxx.xxx.xxx „reboot“ (restart the system). 6. Deactivate DHCP: DHCP-CLIENT=OFF 10. Connect the LANTIME with your network and start the WEB interface in your browser via the configured IP-Address. MEINBERG Radio Clocks - www.meinberg.de 2013-07 Page 2...

This manual is also suitable for:

Lantime m100Lces