Max liquid temp without cool-
ing or quenching
Max liquid temp with quench-
ing gland and bearing cool-
ing
†Max suction pressure is 240 PSIG
*Gland quenching recommended on hot water above 212°F
7.9 Pressure & Temperature Capability
Code for Pressure - Temperature Chart
Group
Curve
A
M
B
C
D
S
E
F
I
L
J
K
3316 Installation, Operation and Maintenance Instructions
Group S
Acceptable minimum standard ANSI mating flanges and
Casing
Material
Suction
316 SST
300 PSI flat face 316 SST
Bronze
300 PSI flat face bronze
C1
250 PSI flat face cast iron
316 SST
300 PSI flat face 316 SST
Bronze
300 PSI flat face bronze
C1
250 PSI flat face cast iron
316 SST
300 PSI flat face 316 SST
Bronze
300 PSI flat face bronze
C1
250 PSI flat face cast iron
7.9 Pressure & Temperature Capability
Group M
250°F
350°F
fittings
Discharge
300 PSI flat face 316 SST
300 PSI flat face 316 SST
300 PSI flat face bronze
250 PSI flat face cast iron
Group L