Download Print this page
Stelpro STE403NP User Manual

Stelpro STE403NP User Manual

Single programming electronic thermostat
Hide thumbs Also See for STE403NP:

Advertisement

Quick Links

User's gUide
sTe403NP
SINGLE proGrammING ELEctroNIc thErmoStat
For further information or to consult this guide online, please visit our website at www.stelpro.com
INSSTE403NP0315

Advertisement

loading
Need help?

Need help?

Do you have a question about the STE403NP and is the answer not in the manual?

Questions and answers

Summary of Contents for Stelpro STE403NP

  • Page 1 User’s gUide sTe403NP SINGLE proGrammING ELEctroNIc thErmoStat For further information or to consult this guide online, please visit our website at www.stelpro.com INSSTE403NP0315...
  • Page 2 DEScrIptIoN WArNiNg The electronic thermostat STE403NP can Before installing and operating this product, the be used to control electric heating units owner and/or installer must read, understand and such as electric baseboards, convectors, or follow these instructions and keep them handy aeroconvectors.
  • Page 3: Wire Installation

    aluminium wires, you must use CO/ALR INStaLLatIoN connectors. Please note that thermostat Selection of thermostat location does not have polarity. The thermostat must be mounted on a 2-wire installation connection box on a wall facing the heating unit, at around 1.5 m (5 feet) above the floor level, on a section of the wall exempt from pipes or air ducts.
  • Page 4 4. Using a screwdriver, loosen the screw 6. Reinstall the front part of the thermostat on retaining the mounting base and front part of the mounting base and tighten the screw at the thermostat. Remove the front part of the the bottom of the unit.
  • Page 5 opEratIoN Ambient temperature / Timer Modes: Frost free, Day, Heating Night, power Fan, used Single indicator programming Temperature Set point set point lock Button to decrease Button to increase set point / timer set point / timer 347V INSSTE403NP0315...
  • Page 6 Night mode selected. The standard factory set ambient temperature point adjustment is 21°C for the Day mode, and The figures displayed above the icon 18°C for the Night mode. indicate the ambient temperature, ± 0.5 degree. The current Day/Night mode Temperature can be displayed in degrees selection is indicated on the Celsius or Fahrenheit (see “Display in degrees...
  • Page 7 selected. Night mode timer adjustment procedure 1. If necessary, adjust the Day/Night mode Single programming mode set points at the desired temperatures. If The Single programming mode, which is needed, switch from one mode to the other associated to the Night mode timer, allows by simultaneously pressing down the two alternating between the Day/Night modes and buttons and releasing them immediately.
  • Page 8 4. When the adjustment is completed, release Adjustment procedure of the Single the buttons and wait for 5 seconds to exit the programming mode: adjustment function. 1. If necessary, adjust the Day/Night set point at the desired temperatures. If needed, NOTE: It is always possible to manually switch from one mode to the other by change the Day/Night mode during a 24-hour...
  • Page 9 Frost-free warning Fan mode The Snowflake icon is displayed when the When the thermostat is used to control a temperature set point is between 3°C (37°F) heating system equipped with a fan, the Fan and 5°C (41°F). A minimum temperature will be mode MUST be activated.
  • Page 10 NOTE: If the thermostat isn’t unlocked within Lock option 5 minutes after the restoration of the power It is possible to impose a maximum temperature supply, the Lock icon will stop to blink and it will set point by activating this mode. Then, it be impossible to unlock the thermostat unless becomes impossible to exceed this set point, cutting off the power supply again.
  • Page 11 troubLEShootING ProbleM DeFeCTIVe PArT or PArT To CHeCK • In normal operating conditions, the thermostat housing can reach nearly The thermostat is hot. 40°C at maximum load. That is normal and will not affect the effective operation of the thermostat. •...
  • Page 12: Technical Specifications

    0°C to 40°C (32°F to 99.5°F) transport, and installation. temperature display resolution: E-mail: contact@stelpro.com 0.5°C (0.5°F) Web site: www.stelpro.com temperature set point range: 3°C to 30°C (37°F to 86°F) temperature set point increments: 0.5°C (1°F) Storage temperature: -20°C to 50°C (-4°F to 120°F)