3-4-3. Removal of the slider holder

Remove the four M2.6 mounting screws for the slider
holder and then remove the slider holder itself.
After removing the slider holder, once again check for
shifting in the mounting position and confirm that the slider
is not mounted tilted.
• Be sure to adhere the screening label (accessory) to cover
the screw holes after removing the slider holder. If these
holes are not plugged, chips, cutting oil or dust may enter
and the accuracy of the scale may be deteriorated.
Use a ball-point pen to enter the mounting date and name
of the person responsible on the label.
Remove the four M2.6 screws.
Slider holder
Adhere the screening label
(accessory).
Fig. 3-13 Removal of slider holder
Note
Keep slider holder and four M2.6 screws after the installation.

3-4-4. Checking of the operating range

After mounting the scale and slider, make sure to confirm
the effective length of the scale and that the movement of
the machine is within the scale's effective length.
Remember that the scale may be damaged if the machine
moves beyond the movable range of the slider (measuring
length + leeway).