Mercury  Hub PR0017 User Manual

Mercury Hub PR0017 User Manual

Mercury hub user guide

Advertisement

Quick Links

Mercury Hub
PR0018 (Mains Powered)
PR0017 (Mercury Controller Powered)
Ensure that all power is
switched off before
installing or maintaining
this product
Mercury Hub User Guide
Mercury 6-5 M/E Installation guide
User Guide
Revision 1.5
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mercury Hub PR0017 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercury Mercury Hub PR0017

  • Page 1: User Guide

    Mercury Hub User Guide Mercury 6-5 M/E Installation guide Mercury Hub User Guide PR0018 (Mains Powered) PR0017 (Mercury Controller Powered) Ensure that all power is switched off before installing or maintaining this product Revision 1.5 Page 1 of 6...
  • Page 2 Table of Contents: THE MERCURY HUB... 3 Description ... 3 Front View ... 3 Rear View... 3 Top View ... 4 Connection to Mercury Controllers: ... 4 RS232 Lead Lengths ... 4 Connection to other IP equipment... 4 Connection to another Mercury Hub or Other Ethernet Hub/switch... 4 Connection to a Data Manager/Director ...
  • Page 3 Description The Mercury Hub is a device that allows up to 10 RDM controllers to be connected to an IP network, with out the need for individual IP Futura modules. The Hub can be mains powered, or powered from 2 connected Mercury controllers.
  • Page 4 Top View Vac (Option) 100 - 250 Vac Power 50 - 60Hz Power On LED Connection to Mercury Controllers: Using a standard CAT5 patch lead, connect the serial output of the RDM Controller to one of the RS232 ports of the Mercury Hub. RS232 Lead Lengths For mains powered hubs, patch lead maximum length must not exceed 15 metres.
  • Page 5 10 Base T connectors The three 10Base T connectors have 2 leds on them: The green LED; when static, indicates that the connection to the device is good, the green LED then flickers when data is being transmitted. The amber LED indicates there is an error or fault on that channel. Network ID The 3-character network ID is made up from the positions of the 2 rotary switches and the RS232 connector number.
  • Page 6 Power requirements: Supply Voltage Range: 100 - 240 Vac ±10% (Mains version) Supply Frequency: 50 - 60 Hz (Mains version) 2 x Mercury Controllers connected to ports 1 and 2 Maximum supply current: 500 mAmps Typical supply current: <100 mAmps Operating temperature range: Operating Humidity: 80% maximum...