Initializing the DME64N/
DME24N
The DME64N/DME24N and ICP1 internal memories
can be initialized as follows.
Begin with the power turned off. Turn the power on while
holding the [SCENE] and [ENTER] buttons, and
continue to hold those buttons until the Yamaha logo
appears.
The initialization screen will appear, allowing you to
choose one of the following three options.
SCENE
SCENE
HOME
HOME
UTILITY
UTILITY
LEVEL
LEVEL
1.Holding down the [SCENE] and [ENTER] buttons
Plug the PA-300 AC adaptor while
holding down the [SCENE] and
[ENTER] buttons
01.Initialize DME:
All scenes, preset parameter settings and WAVE files except
components and files saved via the File Storage function
will be deleted. All UTILITY settings are reset to their
default values.
02.Delete All Data:
All internally-stored components, scenes, preset
parameters, wave files, and files stored using the File
Storage function are erased. All UTILITY settings are reset
to their default values. Use this problem when a problem
occurs with the data stored in the device. After
initialization all necessary components will need to be
resent from the DME Designer application.
03. ==> Exit Diag Mode:
Exits from the initialization screen and restarts the unit.
Do not turn off the power during initialization. Doing so
can damage the device.
MUTE
MUTE
CANCEL
CANCEL
ENTER
ENTER
2.Press the
[POWER]
button

Initializing the DME64N/DME24N

DME64N/DME24N Owner's Manual