DEVIreg™ 850 IV User Manual 1�1 System overview The DEVIreg™ 850 IV system is capable of keeping outdoor areas free of ice and snow. The DEVIreg™ 850 IV can handle up to 2 independent areas, in any of the following combinations: •...
Page 4
DEVIreg™ 850 IV When more than 1 area is controlled by the DEVIreg™ 850 system, it is also possible to prioritize the areas. Prioritizing makes it possible to operate 2 areas, even if the needed power for 2 areas is not present. The DEVIreg™...
DEVIreg™ 850 IV 1�2 General use The DEVIreg™ 850 is operated via 3 buttons and an alpha numeric display capable of displaying information in various languages. Buttons The functions of the 3 buttons are: Info Shows additional information / help (Only active when lit) Next Next menu entry / next line / next letter Enter...
Page 6
DEVIreg™ 850 IV Combined view (default): The combined view shows the status of both systems at A: ROOF the same time. System A is shown on the upper display B: GROUND line, and System B is shown on the lower display line. This view gives the user a quick overview of all the systems.
DEVIreg™ 850 IV 1�3 Possible alarms during operation Clogged drain Description: When clogged drain warning has been enabled, an alarm is raised when the system constantly has been detecting moisture for 14 days. If the DEVIreg™ 850 controls more than 1 system, and prioritiz- ing has been enabled, the time before clogged drain warning- for the down-prioritized system, can be much longer.
DEVIreg™ 850 IV 1�4 Changing parameters and performance of systems Several parameters for each system can be changed during and after the installation. For a complete understanding of how these parameters affect the performance of the roof and ground system, please refer to Appendix B: “How it works”. Only change the DEVIreg™...
Page 9
DEVIreg™ 850 IV Ground system Melting temperature Changing the melting temperature will affect when the system is activated in case of moisture and low temperatures. The factory setting is 4 °C. This means that the heating system will be activated if the temperature falls below 4 °C and moisture is detected.
DEVIreg™ 850 IV Installer Manual 2�1 System overview The DEVIreg™ 850 can handle up to 2 independent areas, in any of the following combinations: • Single roof system (1 system, 1–4 roof sensors) • Single ground system (1 system, 1–4 roof sensors). •...
DEVIreg™ 850 IV 2�2 Placement The DEVIreg™ 850 and power supply are designed for DIN rail mounting. When mount- ing please be aware of the following conditions: The DEVIreg™ 850 is designed and approved to operate in the temperature range –10 °C to 40 °C. The DEVIreg™...
Page 12
DEVIreg™ 850 IV Fig� A — Connection of DEVIreg™ 850 IV DEVIbus sensors White White Black White White Black DC output DC supply – – – 13 14 15 16 17 18 19 20 21 22 23 24 PSU 24 VDC DEVIreg™...
Page 13
DEVIreg™ 850 IV Installer Manual Fig� B Fig� C 230 V cables, 1–3 P/1–3 loads — System A 230 V cables, 1–3 P/1–3 loads — System B 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 DEVIreg™...
Page 14
DEVIreg™ 850 IV Fig� D Fig� E 400 V cables, 2–3 Phase/1–3 Loads — System A 400 V cables, 2–3 Phase/1–3 Loads — System B 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 DEVIreg™...
Please follow the general description and finally select the installation scenario according to the system type. Change setting with key: Accept setting with key: General Power on DEVIreg™ 850 IV WELCOME TO DEVIREG 850 IV Select language SELECT LANGUAGE: ENGLISH System is being checked… CHECKING SYSTEM <-------->...
Page 16
DEVIreg™ 850 IV Installation of roof system The installation of a DEVIreg™ 850 with 1 roof system has been selected. It is optional if the sensors are connected to the DEVIreg™ 850 before power on or during the installation. The system uses the output System A. If sensors for System A are not connected —...
Page 17
DEVIreg™ 850 IV Installation of ground system The installation of a DEVIreg™ 850 with 1 ground system has been selected. It is optional if the sensors are connected to the DEVIreg™ 850 before power on or during the installation. The system uses the output System A. If sensors for System A are not connected —...
Page 18
DEVIreg™ 850 IV Installation of combi system The installation of a DEVIreg™ 850 with 1 roof and 1 ground system has been selected. It is optional if the sensors are connected to the DEVIreg™ 850 before power on or during the installation.
Page 19
DEVIreg™ 850 IV SYSTEM B! when all sensors for System B are found… Press INSTALLED System B is installed… CHECKING SYSTEM System is being checked… <--------> CONFIG SYSTEM: SYSTEM A Press to select system to configure. CONFIG SYSTEM: Press to configure selected system (naming SYSTEM B sensors, changing factory settings and setting priorities.) Please refer to “Changing parameters and performance of systems”...
Page 20
DEVIreg™ 850 IV Installation of dual system The installation of a DEVIreg™ 850 with 2 roof systems or 2 ground systems has been selected. It is mandatory that no sensors or only sensors for System A are connected to the the DEVIreg™...
Page 21
DEVIreg™ 850 IV SYSTEM B! when all sensors for System B are found… Press INSTALLED System B is installed… System is being checked… CHECKING SYSTEM <--------> CONFIG SYSTEM: SYSTEM A Press to select system to configure. CONFIG SYSTEM: Press to configure selected system (naming SYSTEM B sensors, changing factory settings and setting priorities.) Please refer to “Changing parameters and performance of systems”...
DEVIreg™ 850 IV 2�5 Modification of system(s) It is possible to modify the installed systems on the DEVIreg™ 850. The following modifi- cations are possible: • Reactivate passive sensors • Replace a malfunctioning sensor • Add an extra sensor When the DEVIreg™ 850 cannot communicate with a sensor, the DEVIreg™ 850 reports the error: “Errors detected!”.
Page 23
DEVIreg™ 850 IV Replacing a malfunctioning sensor From the installer menu select Change system. The CHECKING SYSTEM system is searching for connected sensors. <--------> The user selects the passive sensor, which should be REPLACE SENSOR: replaced with a new one. SENSOR1 03FB2F REPLACE SENSOR: Press...
DEVIreg™ 850 IV 3�2 Factory settings Roof System Function Factory settings Range/Options Moisture level 5 to 95 (5 being the most sensitive to moisture) Melting temperature 1.5 °C 0.0 °C to 9.9 °C Post-heat 1 hour 0 to 9 hours Clogged drain On/off System mode...
Page 29
DEVIreg™ 850 IV Change system Change system Only if any passive (disabled) sensors are working again! If no new sensor(s) found If new sensor(s) found, but no If new sensor(s) found and (Example showing ground passive sensor(s) found.
DEVIreg™ 850 IV How it works Roof system Standby The roof system is fully (No heating) Temperature > automated. It gathers in- Temperature < Melting temperature Melting temperature formation on moisture and Moisture > Moisture limit Measuring After 3 hours and temperature via digi- Melting temperature...
Page 32
DEVIreg™ 850 IV Ground system Temperature < The ground system is fully Standby temperature Standby Standby Temperature >- automated. It gathers in- (No heating) Standby temperature Mantaining stand- formation on moisture and by temperature Temperature < Melting temperature (Heating) temperature via digital sen- and Moisture >...
Page 33
DEVIreg™ 850 IV Post-heating If the reason for ending a heating period is a decrease of moisture to below the chosen level, the post-heating period will start. Post-heating ensures that no ice and snow is left on the roof. If system priority is low, heating might be paused at any time! The ground system uses heated sensors which under normal circumstances will hold a temperature of 1.5 °C.
Page 34
DEVIreg™ 850 IV Security and energy consumption High security — higher energy consumption If a high degree of security against ice and snow is wanted, make the following adjust- ments of the operation parameters: • Increase the standby temperature • Increase the melting temperature •...
DEVIreg™ 850 IV PSU and feeder cable Note: max. 3 m length of the cable between the PSU and the 850 controller. Ground system 2 pcs. PSU 24 VDC, 1 pcs. PSU 24 VDC 24 W 24 + 24 W in parallel** Number 1 or 2 * of sensors:...
DEVIreg™ 850 IV Warranty At DEVI, we find it of great importance to deliver • Power supply units for thermostats; high quality products with long lasting effects. • All related accessories, including heating cables, and heating mats accessories. DEVIwarranty™ is a series of 4 individual, best-in- market warranties to give you full peace of mind Should you, against all expectations, experience a while using DEVI products in electric heating...
Page 37
See other conditions on previous page. Electrical Installation by: Installation date: Type of thermostat: Production code: Suppliers Stamp: Danfoss A/S Electric Heating Systems Phone: +45 7488 8500 Ulvehavevej 61 Fax: +45 7488 8501 7100 Vejle E-mail: EH@DEVI.com Denmark www.DEVI.com...
Page 38
DEVIreg™ 850 IV Installation instruction...
Page 39
DEVIreg™ 850 IV Installation instruction...
Page 40
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter itsproducts without notice. This also applies to products already on order provided that such alterations can be made without subsequential changesbeing necessary in specifications already agreed.
Need help?
Do you have a question about the DEVIreg 850 IV and is the answer not in the manual?
Questions and answers