Download Print this page

Philips SOPHO Call@Net Manual page 95

Data facilities explained

Advertisement

PARAMETERS
CT108 as request:
CT108 assumed on:
CT105 as request:
CT103 as request
CT107 as clear:
CT107 assumed on:
Auto answer:
Connect
CT105&CT109:
CT109 enables CT106:
Connect
CT105&CT106:
CT105 assumed on:
Dataguarding:
Incoming guarding:
Break call clear:
Autobaud detection:
Autoparity detection:
Flow control:
CT142 control:
Dataguard (min):
Table C-1 Default Parameter Settings of SOPHO-LAM in DTE-mode.
For correct convertor operation, in general the convertor modem has to operate as follows:
-
CT125 indicates an incoming call;
-
when CT108 changes from ON to OFF, the modem has to go on hook;
-
CT109 indicates detection of an incoming carrier;
-
for synchronous transmission the modem should accept the transmit clock from the
SOPHO-LAM on CT113;
-
CT107 indicates the condition of the analogue line (normal operation according to V.24
DEFAULT
PARAMETERS
SETTINGS
No
Incoming guard (sec):
No
Xon character:
No
Xoff character:
No
Transmission:
No
Mode:
No
Speed:
Yes
Format (bits):
No
Format (parity):
No
Format (stopbits):
No
Echo characters
No
Upper case:
No
Calling number:
No
Flow control:
No
NIC:
No
Rate adaption:
No
Protocol:
Xon/Xoff
Logoff:
Auto
Password:
3 minutes
DEFAULT
SETTINGS
60 seconds
017
019
Asynchronous
Full duplex
1200 bits/sec
8 bits
No parity
1 stop bit
Yes
Yes
No
No
Yes
Proprietary
Keyboard
No logoff string
PROGRAM DCE