Installation And Commissioning; Installing The Hardware; Ktp400; Logo! 8 - Siemens SIMATIC HMI KTP400 Manual

House control with weather sensors
Hide thumbs Also See for SIMATIC HMI KTP400:
Table of Contents

Advertisement

4 Installation and Commissioning

Installation and Commissioning
4
Note
Please also observe the information on installation and commissioning in the
Set_9
and
separately.
4.1

Installing the hardware

Table 4-1
1.
Create Sets 9, 10 and 11 as shown in
2-1.
2.
Connect the sets with LAN cables
4.1.1

KTP400

Note
Observe the setup guidelines for the KTP400. Further information can be found
in the KTP400 Basic Panel "Manual".
IP addresses and subnet masks
Make sure that the KTP400, your PC and the hardware setup from LOGO! Set 9
and LOGO! Set 10 are in the same IP address range, as shown in the following
table.
Table 4-2
No.
1.
KTP400 weather station (Set 11)
2.
KTP700 (Set 10)
3.
LOGO! weather station (Set 11)
4.
Master LOGO! (Set 9)
5.
Slave LOGO! (Set 9)
6.
LOGO! TDE (Set 9)
7.
Network card or USB Ethernet Adapter for network
connection to PC
4.1.2

LOGO! 8

Note
Changes of the IP address or the master-slave mode are only possible in
"STOP" mode.
House Control and Weather Sensors - LOGO! Set 11
Entry ID: 68585346,
V2.1,
Set 10
documentation, unless you would like to operate Set 11
Action
Figure
Device
09/2018
Comment
Set 11 can be used separately, without
connecting other sets.
Set 11 can also be used only with Set 9.
For this, the LOGO! software from Set 11
must be used for house control
IP address
192.168.1.80
192.168.1.20
192.168.1.13
192.168.1.10
192.168.1.11
192.168.1.14
192.168.1.12
Subnet mask
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
14