Assembly/Installation
4
Connection and terminal description of the DEH21B option
4.5
Connection and terminal description of the DEH21B option
Part number
Front view of
Description
DEH21B
X62: Connection absolute
DEH21B
encoder
9
5
6
1
X60: Power supply
1
2
X15: Motor encoder input
8
15
9
1
62700AXX
16
Encoder card option DEH21B: 1820 818 5
NOTE
The DC 24 V power supply of an encoder connected to X62 is ensured when X60 is
supplied with DC 24 V. Observe the 'Project Planning' chapter in the MOVIDRIVE
MDX60B/61B system manual.
Terminal
X62:1
X62:2
X62:3
X62:4
X62:5
X62:6
X62:7
X62:8
X62:9
X60:1
X60:2
X15:1
X15:2
X15:3
X15:4
X15:5
X15:6
X15:7
X15:8
X15:9
X15:10
X15:11
X15:12
X15:13
X15:14
X15:15
STOP!
Encoders connected to X15 and X62 must not be installed or removed during opera-
tion.
Electrical components in the encoder or on the encoder card could be destroyed.
De-energize the inverter before plugging or removing the encoder connections. Switch
off the mains voltage and the DC 24 V (X10:9 at the inverter and X60:1 at the DEH21B
option).
NOTE
The DC 12 V supply voltage from X15 is sufficient to operate SEW encoders (except
HTL encoders) with a DC 24 V supply voltage. With all other encoders, check whether
they can be connected to the DC 12 V supply voltage.
Manual – MOVIDRIVE® MDX61B DIP11B / DEH21B Absolute Encoder Cards
Function
Data +
Reserved
Cycle +
Reserved
DGND
Data –
Reserved
Cycle –
DC 24 V output
24VIN
DGND
(COS+) signal track A (K1)
(SIN+) signal track B (K2)
Signal track C (K0)
DATA +
Reserved
Reference potential TF/TH/KTY–
Reserved
Reference potential DGND
(COS–) Signal track A (K1)
(SIN–) Signal track B (K2)
Signal track C (K0)
DATA -
Reserved
TF/TH/KTY+ connection
DC+12 V (tolerance range DC 10.5 ... 13 V)
(max. load DC 650 mA)
®