Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type H) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols

3.2.19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)

4-24-1
SIA Mode Description
Example
<LF><CRC><h><sequence#><receiver#><line#>[#aaaaaa|CCCCsCCCCs
CCCCs CCCCsCCCCsCCCCsC]<CR>
Table 74: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte
Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
CCCC
s
CCCC
s
CCCC
s
CCCC
s
CCCC
s
CCCC
s
C
Figure 22: Message sent to printer
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa
+++sACCTsaaaasCCCCsCCCCsCCCCsCCCC
++++++++++++++CCCCsCCCCsC
For lines that are grouped, Gxx appears instead of Lxx.
64
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical redundancy check number.
h
The message sequence number. The valid sequence number range is 0001
to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
The communicator's account number, up to six digits.
Channels 1 to 4.
One space.
Channels 5 to 8.
One space.
Channels 9 to 12.
One space.
Channels 13 to 16.
One space.
Channels 17 to 20.
One space.
Channels 21 to 24.
One space.
Supervisory channel.