Parameters
List of parameters
07
DI/DO 7 (X520.9)
08
DI/DO 8 (X521.2)
09
DI/DO 9 (X521.3)
10
DI/DO 10 (X522.4)
11
DI/DO 11 (X521.5)
12
DI/DO 12 (X521.6)
13
DI/DO 13 (X521.7)
14
DI/DO 14 (X521.8)
15
DI/DO 15 (X521.9)
16
DI/DO 16 (X522.2)
17
DI/DO 17 (X522.3)
18
DI/DO 18 (X522.4)
19
DI/DO 19 (X522.5)
20
DI/DO 20 (X522.6)
21
DI/DO 21 (X522.7)
22
DI/DO 22 (X522.8)
23
DI/DO 23 (X522.9)
Note:
DI/DO: Bidirectional Digital Input/Output
r4052[0...1]
CO: TB30 analog inputs, actual input voltage / TB30 AI inp_V
TB30
Can be changed: -
Data type: Floating Point
P-Group: Terminals
Not for motor type: -
Min
- [V]
Description:
Displays the actual input voltage at the analog inputs of the Terminal Board 30 (TB30).
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Note:
AI: Analog Input
r4052[0...1]
CO: TM31 analog inputs, actual input voltage/current / TM31 AI inp_V/I
TM31
Can be changed: -
Data type: Floating Point
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Displays the actual input voltage in V when set as voltage input.
Displays the actual input current in mA when set as current input and with the load resistor switched-in.
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The type of analog input AI x (voltage or current input) is set using p4056.
Refer to: r4056, p4056
Note:
AI: Analog Input
r4052[0...0]
CO: TB41 analog inputs, actual input voltage / TM41 AI inp_V
TM41
Can be changed: -
Data type: Floating Point
P-Group: Terminals
Not for motor type: -
Min
- [V]
Description:
Displays the actual input voltage in V.
1-794
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
I/O with time
Calculated: -
Dynamic index: -
Units group: -
Max
- [V]
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
- [V]
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
I/O
-
Access level: 1
Func. diagram: 9104
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 9566, 9568
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 9663
Unit selection: -
Expert list: 1
Factory setting
- [V]