Calibration Procedure - Graco Reactor 2 E-30 Repair And Parts Manual

Proportioning proportioning system
Hide thumbs Also See for Reactor 2 E-30:
Table of Contents

Advertisement

Repair

Calibration Procedure

Procedure
Calibration
Calibration
Procedure
NOTICE
NOTICE
NOTICE
To prevent damage to the heated hose, a hose
calibration is required if any of the following
conditions are true:
• The hose has never been calibrated before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
NOTE: The Reactor and heated hose must be at the
NOTE:
NOTE:
same ambient temperature to get the most accurate
calibration.
1. Enter Setup Mode and navigate to System
screen 3, then press the Calibrate soft key
2. Press the Continue soft key
the reminder to have the hose at ambient
conditions.
72
3. Wait while the system measures the hose
.
to acknowledge
resistance.
NOTE: If hose heat was on prior to the calibration
NOTE:
NOTE:
procedure, the system will wait up to five minutes
to allow the wire temperature to equalize.
NOTE:
NOTE: The hose temperature must be above 32
NOTE:
°F (0 °C) during calibration.
333024S

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Reactor 2 E-30 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Reactor 2 e-xp2Reactor 2 e-30 eliteReactor 2 e-xp2 elite e-xp2E-xp2 elite

Table of Contents