General product presentation and operating principal Safety recommendations III. Content Technical data and dimensions Product installation V.1 Siting V.2 Support V.3 Handling V.4 Connection to the hydraulic circuit V.5 Wiring V.6 Heating priority Start up and operation VII. Upkeep and maintenance VII.1 –...
Page 3
Warning: Please read the following tips before installation, use and maintenance. Installation, removal and maintenance must be carried out by qualified professional in accordance with the instructions. Gas leakage test must be done before and after installation. 1. Use It must be installed or removed by professionals, and it is forbidden to dismantle and refit without permission.
Page 4
Installation must be stopped if any gas leakage. 3. Transportation & Storage Sealing is not allowed during transportation Transporting goods at a constant speed is needed to avoid sudden acceleration or sudden braking, so as to reduce the collision of goods. The unit must be far away from any source of fire.
Page 5
I. General product presentation and operating Fairland Inverter water/ air heat pumps are purpose designed to heat or cool swimming pools. Performance data is only guaranteed for this specific application. Water / air heat pumps are an efficient inexpensive means of heating swimming pool water. The device exploits the thermodynamic properties of heat transfer fluids when subjected to the well known compression –...
VI. Technical data and dimensions Operating range: outdoor ambient air temperature between -7°C and +43°C. Performance levels are maximised between +15°C and +25°C. The machine is not guaranteed to run properly outside the -7°C / +43°C operating range. Water resistance index for electrical parts : IPX4. Set point temperature regulation range: •...
Dimensions in mm Model IPHCR15 IPHCR20 IPHCR26 IPHCR33 IPHCR40 IPHCR45 IPHCR55 IPHCR70 1084 IPHCR70T 1084 IPHCR100T 1154 Nota bene: technical data and dimensions may be subject to modification, without notification, over time due to product improvements. For more detail, refer to the information plate on the machine. When the weather is cold and damp, frost can build up on the evaporator fins.
Pay attention to the proximity of deciduous vegetation. Leaves, flowers, pollen, etc. could be drawn in by the fans and obstruct the gratings. Proximity to neighbours Quite apart from the heat pump’s intrinsic acoustic level, (measured in a laboratory according to standardized methods and on standardised installations) the installer is responsible for ensuring that the installation site will not cause a phonic nuisance to neighbours, and take any necessary steps.
Page 9
between the two tapping points (valve to control the flow rate through the heat pump). To limit heat loss from the pipes, bury them underground (at a depth of 50 to 80 cm depending on the region) or lag the pipes. In any case, minimize the amount of uninsulated pipe exposed to the air. V.5) Wiring The machine must be wired in by a qualified professional, after the hydraulic connections have been completed.
V.6) Heating priority : It is possible to set the system up so that the heat pump will start up filtration outside programmed filtration cycles if a heating demand is detected. This allows the pool water temperature to be held more constantly around the set point.
Page 11
Cooling indicator Auto mode icon Heating indicator Compressor running Water at the inlet Current power, in % of max. power Water temperature at the inlet Water temperature Smart/Silence mode at the outlet Water at the oulet Symbol Designation Function ON/OFF Power on/off Lock-unlock / Locking / unlocking the screen...
Page 12
When this function is active, the set temperature can be fixed between 12 and 35°C. The heating function only enables to increase the water temperature. If the water temperature overpasses the set value due to the ambiant conditions, the heatpump keeps off, and will not cool the water. Thus, this function is to be activated only when the pool water temperature is likely to decrease spontaneously.
When the heat pump is busy heating the water, the operator can also starts a defrosting cycle manually if it appears suitable (for example, where a high amount of frost has not been totally eliminated by the defrosting cycle). For this, press simultaneously for 5 seconds.
Displayed code Not Fault description No water protection Power supply excesses operation range Excessive temp difference between inlet and outlet water(Insufficient water flow protection) Ambient temperature too high or too low protection Anti-freezing reminder Displayed code Fault description High pressure protection Low pressure protection 3 phase sequence protection (three phase only) Water outlet temp too high or too low protection...
Page 15
The following table describes situations that may seem abnormal although no error code is displayed on the machine. For any other problems, please contact the seller. Problem Possibles causes Possible solutions Check that no circuit breakers are No power supply tripped The heat pump will Check that the electrical connections...