Siemens SINUMERIK 840D Description Of Functions page 429

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
7.6.4
Configuring and connecting-up the ET200S I/O
PROFIBUS connection
Only the part required for the PROFIBUS connection of the ET 200S line is
(overall system)
displayed here:
(0) 840D NCU 57x.4
SI PLC315-2DP 2AF03
2
X2
DP
3
IM 360
4
S7 FM-NCU
Fig. 7-34
STEP 7 Hardware configuration: Definition of the PROFIBUS system
The system requirements regarding the NCU hardware and interface module
must be observed (cf. Chapter 3.12 -> SI I/Os using fail-safe modules on
PROFIBUS-DP -> System requirements).
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
7.6 SI I/Os using fail-safe modules connected to PROFIBUS DP
Note
When describing how the F I/Os are configured, the associated parameters
are only described to some extent or only in the form of an overview. More
detailed information is given in the context-sensitive online help and in the
manual ET200S Distributed I/O System, Fail-Safe Modules .
7 Configuring example
PROFIsafe: DP master system (1)
(8) IM 151
HWKonf_Bus.dsf
7-429

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents