END USER GUIDE
RCI DE8310 V1.6
DELAYED EGRESS V1.6 ELECTROMAGNETIC LOCKS
PLEASE GIVE TO END USER
Normal Conditions: In normal conditions with the door closed and locked.
System Status
Light Panel *
Door Locked
Green
Nuisance Period: Some installations have a short nuisance period set to accommodate accidental triggering.
If the pressure on the door is withdrawn during the nuisance delay period, the system returns to normal conditions on its own.
System Status
Light Panel *
Nuisance Delay
Blinking Red
Period
fast
To Exit: If a Nuisance Delay is enabled, maintained pressure past its time will start the irreversible release delay.
If a Nuisance Delay is not enabled, slight pressure will start the irreversible release delay.
The release delay time is posted on the door.
Pressure is no longer required on the door.
The lock will release when the delay period ends.
The system now needs to be manually RESET using the keyswitch in order for the buzzer to stop.
System Status
Light Panel *
Release Delay
Blinking Red -
Period
slowly
Lock Release
Blinking Red & Green -
alternately
To By-Pass the Delay Period and Exit: Manually OVERRIDE using the keyswitch to release the door.
When the door closes, the system returns to normal conditions.
System Status
Light Panel *
Exit Switch to Open
Red
(Authorized Exit)
Door Forced Open: If this happens before the release delay period has lapsed, the buzzer indicators can only be turned off by switch-
ing the system power off.
System Status
Light Panel *
Forced Open
Blinking Red - Fast
ZLDE8310EUG-V16
Local Buzzer
(if connected)
OFF
Local Buzzer
(if connected)
Pulsing Sound
Local Buzzer
(if connected)
Steady Sound
Steady Sound
until reset
Local Buzzer
(if connected)
OFF
Local Buzzer
(if connected)
Pulsing Sound
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Local Alarm Relay Output
(if connected)
OFF
Local Alarm Relay Output
(if connected)
ON
Local Alarm Relay Output
(if connected)
ON
ON
Local Alarm Relay Output
(if connected)
OFF
Local Alarm Relay Output
(if connected)
ON
Remote Alarm Relay Output
(if connected)
ON
Remote Alarm Relay Output
(if connected)
ON
Remote Alarm Relay Output
(if connected)
OFF
OFF
Remote Alarm Relay Output
(if connected)
OFF
Remote Alarm Relay Output
(if connected)
OFF
PCN18041
R01-20GR
Need help?
Do you have a question about the RCI DE8310 V1.6 and is the answer not in the manual?
Questions and answers