HRRS Series WARRANTY We warrant that this product is free from defects in material and workmanship and, when properly used, will perform in accordance with applicable IET specifications. If within one year after original shipment, it is found not to meet this standard, it will be repaired or, at the option of IET, replaced at no charge when returned to IET.
HRRS Series Figures and Tables Figure 1.1. HRRS Series High Resistance Decade Substituter ....1 Figure 2.1 Operating Guide Affixed to Unit ........... 3 Figure 5.1 HRRS Series Schematic Diagram ........10 Table 5.1 Model Reference Codes ............11 Table 5.2 Replacement Parts List ............11 Table 5.3 Commercial and Government Entity CAGE Codes ....
HRRS Series WARNING OBSERVE ALL SAFETY RULES ‘WHEN WORKING WITH HIGH VOLTAGES OR LINE VOLTAGES. ELECTRICAL SHOCK HAZARD. DO NOT OPEN CASE. REFER SERVICING TO QUALIFIED PERSONNEL. HIGH VOLTAGE MAY BE PRESENT WITH HIGH VOLTAGE OPTIONS. WHENEVER HAZARDOUS VOLTAGES (> 45 V) ARE USED, TAKE ALL MEASURES TO...
These instruments The HRRS Series employs state of the art precision are useful developments tool wherever small currents resistors, of various types for high accuracy, high sta- and high resistances are required, such as insulation...
HRRS Series Chapter 2 SPECIFICATIONS For convenience to the user, the pertinent specifications are given in an OPERATING GUIDE, shown in Figure 2.1, affixed to the case of the instrument. SPECIFICATIONS Decade Resistance Accuracy Option** Max Voltage 5 kV Max Temp.
3.3 Repackaging for Shipment plications. If the instrument is to be returned to IET Labs, con- Save all original packing material for convenience in tact the Service Department at the number or address,...
HRRS Series 3.4 Storage tended exposure to such temperatures can result in If this instrument is to be stored for any lengthy pe- an irreversible change in resistance, and require riod of time, it should be sealed in plastic and stored recalibration in a dry location.
4.1.1 General Considerations unit may be cleaned with alcohol or naphtha. The HRRS Series Decade unit provides three termi- nals labeled H (high), L (low), and G (ground.) The H and L terminals are connected to the ends of the Keep unit in a sealed environment when resistor being set.
HRRS Series 4.2 Dial Setting and 10-10-10-10.-10 MWs become Whenever the dials are used for positions 0-9, the 1 0 0 0 0 0 . 0 resulting resistance is simply read off from the panel 1 0 0 0 0 . 0 dial setting in a direct fashion.
2. Pry off the cap from the knob It is recommended that service be performed only by (HARS-X-4300-CAP), and remove the nut under it. IET Labs or by qualified personnel. 3. Pull off the knob (HARS-X-4300-KNB), and re- move the nut under it.
Page 16
HARS-X Series Figure 51. HRRS Series Schematic Diagram MAINTENANCE...