Page 1
___________________ Introduction ___________________ Safety notices ___________________ Recommendations on network security SIMATIC NET ___________________ Description of the device Network components Extender for SCALANCE XM-400 ___________________ Installation ___________________ Connecting up Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Approvals 09/2018 C79000-G8976-C332-08...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting extenders within the SCALANCE XM-400 product group. The configuration and the integration of the device in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: ●...
Page 6
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15315/man) Documentation on configuration You will find detailed information on configuring the devices in the following configuration manuals: ●...
Page 7
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support: – Industrial Ethernet / PROFINET Industrial Ethernet System Manual (https://support.industry.siemens.com/cs/ww/en/view/27069465) –...
Page 8
Feed under https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
Page 9
Introduction 1.1 On the Operating Instructions Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
Page 10
Introduction 1.1 On the Operating Instructions Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
● Evaluate your plant as a whole in terms of security. Use a cell protection concept with suitable products (https://www.industry.siemens.com/topics/global/en/industrial- security/pages/default.aspx). ● When the internal and external network are disconnected, an attacker cannot access internal data from the outside. Therefore operate the device only within a protected network area.
Page 14
● Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://www.siemens.com/industrialsecurity) website. ● Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you require to use the device.
Page 15
Recommendations on network security Secure/non-secure protocols and services ● Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non-secure protocols on the device with caution. ●...
Page 16
Recommendations on network security Interfaces security ● Disable unused interfaces. ● Use IEEE 802.1X for interface authentication. ● Use the function "Locked Ports" to block interfaces for unknown nodes. ● Use the configuration options of the interfaces, e.g. the "Edge Type". ●...
Page 17
Recommendations on network security Protocol Protocol/ Default port status Configurable port Authentication Encryption Port number TELNET TCP/23 Open TCP/22 Open HTTP TCP/80 Open HTTPS TCP/443 Open ✓ SNMP UDP/161 Open ✓ (when configured) SNTP UDP/123 Closed ✓ PROFINET UDP/34964, Open UDP/49154, 49155 EtherNet/IP TCP/44818,...
Page 18
Recommendations on network security Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Description of the device Properties and functions SCALANCE XM-400 product group The product group SCALANCE XM-400 consists of basic devices (compact switches) and extenders (port extenders and function extender). SCALANCE XM-400 basic device Basic properties The SCALANCE XM-400 basic devices are modular compact switches with fixed RJ-45 ports (10/100/1000 Mbps) and SFP transceiver slots that can be equipped individually.
Description of the device 4.2 Product overview Port extender PE-400 Port extenders are modular network components with RJ-45 ports (10/100/1000 Mbps) or SFP transceiver slots. To the left they have an expansion interface to connect to the basic device or to another port extender and to the right they have an expansion interface for additional port extenders.
Page 21
Description of the device 4.2 Product overview Function Extender BUS ANALYZER Agent XM-400 Device Properties Article number BUS ANALYZER 4 x internal monitor ports for port mirroring 9AE 4140-2AA00 Agent XM-400 as function extender Type designation The type designation of an extender is made up of several parts that have the following meaning: Interface Property...
Page 22
Description of the device 4.2 Product overview Components of the product The following components are supplied with an extender: ● 1 x Extender ● 1 x Operating instructions ● 1 x Securing screw for mounting on an S7 standard rail The following components are also supplied with a PE408PoE: ●...
Description of the device 4.3 Device views Device views 4.3.1 PE408 The following figure shows an overview of the components of the PE408. ① Electrical ports ② Location for securing to an S7 standard rail (on the underside of the device, not in figure) ③...
Description of the device 4.3 Device views 4.3.2 PE408PoE The following figure shows an overview of the components of the PE408PoE. ① Electrical ports ② Location for securing to an S7 standard rail (on the underside of the device, not in figure) ③...
Description of the device 4.3 Device views 4.3.3 PE400-8SFP The following figure shows an overview of the components of the PE400-8SFP. ① Slots for SFP transceivers ② Location for securing to an S7 standard rail (on the underside of the device, not in figure) ③...
Description of the device 4.4 Accessories Accessories Pluggable transceiver The following SFP transceivers can be used for the port extender: Type Property Article number SFP991-1 1 x 100 Mbps, LC port optical for glass FO cable 6GK5 991-1AD00-8AA0 (multimode), up to max. 5 km SFP991-1 (C) 1 x 100 Mbps, LC port optical, for glass FO cable 6GK5 991-1AD00-8FA0...
Description of the device 4.5 LED display LED display The following figure shows the arrangement of the LEDs. LEDs for displaying the device position L1/L2 LEDs for displaying the PoE power supply (PE408PoE only) LEDs for displaying the port status 4.5.1 LEDs "2"...
Description of the device 4.5 LED display 4.5.2 LEDs "L1" and "L2" Note Only the port extender PE408PoE has the LEDs "L1" and L2". The LEDs "L1" and "L2" display information about the PoE power supply at the connectors L1+/M1 und L2+/M2. From the "L1"...
Page 29
Description of the device 4.5 LED display Meaning in display mode B In display mode B, the port LEDs indicate the transmission speed. LED color LED status Meaning Port operating at 10 Mbps Green Port operating at 100 Mbps Orange Port operating at 1000 Mbps If there is a connection problem and the type of transmission is fixed (autonegotiation off), the desired status, in other words the set transmission speed (1000 Mbps, 100 Mbps, 10...
Description of the device 4.6 Power over Ethernet (PoE) Power over Ethernet (PoE) Function The "Power over Ethernet" function supplies connected devices with power via the Ethernet cable. Devices supplied with power via an Ethernet cable do not require a separate voltage source.
Page 31
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support. (https://support.industry.siemens.com/cs/ww/en/ps/15315) Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Page 32
Description of the device 4.6 Power over Ethernet (PoE) Power supply and pin assignment The voltage is transferred on the data wires 1, 2, 3 and 6 of the Ethernet cable. With the RJ-45 plug, the pin pairs 1/2 are used for the negative and 3/6 for the positive power supply.
Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
Installation 5.2 Types of installation Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN...
Installation 5.3 Installation on a DIN rail Installation on a DIN rail Installation WARNING Danger of injury by falling objects The 35 mm DIN rail does not provide adequate support in shipping or when there is severe vibration (> 10 g). When used under these conditions, the device can detach itself and may cause injury to persons.
Installation 5.4 Installation on a standard S7-300 rail Removal To remove the device from a DIN rail, follow the steps below: 1. If the extender is connected to a basic device, disconnect the extender, see section "Fitting an extender (Page 38)". 2.
Installation 5.5 Installation on a standard S7-1500 rail Removal To remove the device from a standard rail, follow the steps below: 1. Release the screw on the underside of the standard rail. 2. If the extender is connected to a basic device, disconnect the extender, see section "Fitting an extender (Page 38)".
Installation 5.6 Fitting an extender Removal To remove the device from a standard rail, follow the steps below: 1. Release the screw on the underside of the standard rail. 2. If the extender is connected to a basic device, disconnect the extender, see section "Fitting an extender (Page 38)".
Page 39
Installation 5.6 Fitting an extender Types of installation You have the following options when connecting devices: ● You can connect the devices and mount them together on a DIN or S7 standard rail. ● You can mount a device on a DIN or S7 standard rail and expand it later. Note For mounting on a rail as well as for removing from the rail, plan enough space between the devices, see section "Dimension drawings (Page 51)".
Page 40
Installation 5.6 Fitting an extender Removing an extender To remove an extender, follow the steps below: ① 1. Release the locking device using a screwdriver The two devices are separated from each other. ② 2. Pull the two devices apart in a straight line until the two centering pins are completely out of the openings.
Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals, or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70).
Connecting up 6.2 Further notes Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
Connecting up 6.3 PoE power supply of the PE408PoE In areas subject to the NEC or CEC: WARNING Safety notice for connectors with LAN (Local Area Network) marking A LAN or LAN segment, with all its associated interconnected equipment, shall be entirely contained within a single low-voltage power distribution and within a single building.
Page 44
Connecting up 6.3 PoE power supply of the PE408PoE Information on the PoE power supply ● You can connect a different PoE power supply to each of the two connectors, see e.g. section "Accessories (Page 26)". ● Devices capable of PoE can be supplied with power via the ports, see section "Power over Ethernet (PoE) (Page 30)".
Page 45
Connecting up 6.3 PoE power supply of the PE408PoE Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Technical specifications Technical specifications of the PE408 The following technical specifications apply to the port extender PE408. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Transmission speed 10 / 100 / 1000 Mbps Electrical data (supply from basic device) Current consumption at 24 V DC 200 mA...
Technical specifications 7.2 Technical specifications of the PE408PoE Technical specifications of the PE408PoE The following technical specifications apply to the port extender PE408PoE: Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Transmission speed 10 / 100 / 1000 Mbps Electrical data (supply from basic device) Current consumption at 24 V DC...
Technical specifications 7.3 Technical specifications of the PE400-8SFP Technical specifications of the PE400-8SFP The following technical specifications apply to the port extender PE400-8SFP. Technical specifications Attachment to Industrial Ethernet Slots for SFP transceivers Quantity Connector SFP transceivers (LC port) Transmission speed 100 / 1000 Mbps Electrical data (supply from basic device) Current consumption...
Page 50
Technical specifications 7.3 Technical specifications of the PE400-8SFP Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Page 51
Dimension drawings Note Dimensions are specified in mm. Front view Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Page 52
Dimension drawings Side view Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Page 53
Dimension drawings From above Extender for SCALANCE XM-400 Operating Instructions, 09/2018, C79000-G8976-C332-08...
Page 55
You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15312/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
Page 56
EC L174, 01/07/2011, pages 88-110 You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15312/cert). The EC Declaration of Conformity is available for all responsible authorities at:...
Page 57
• On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection • On the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/78381013) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially...
Page 58
Approvals ● nA [op is] ATEX classification: II 3 (2) G Ex nA [op is Gb] IIC T4 Gc Certificate no.: DEKRA 11ATEX0060 X The products meet the requirements of the following standards: – EN 60079-28 (Explosive atmospheres - Part 28: Protection of equipment and transmission systems using with optical radiation) –...
Page 59
Approvals Permitted types of protection The following types of protection are possible: ● nA IECEx classification: Ex nA IIC T4 Gc Certificate no.: DEK 14.0025X The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
Page 60
Approvals Note for devices with CLASS 1 LASER Important note on products certified according to Type Examination Certificate KEMA 07ATEX0145 X as of Issue 95 / DEKRA 18ATEX0025X and IECEx Certificate of Conformity DEK 14.0025X as of Issue 43 / DEK 18.0017X and containing Class 1 optical radiation sources.
Page 61
Approvals cULus approval for industrial control equipment cULus Listed IND. CONT. EQ. Underwriters Laboratories Inc. complying with ● UL 508 ● CSA C22.2 No. 142-M1987 Report no. E85972 cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with ●...
Page 63
Approvals WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above.