Switching On - Stihl SE 122 Instruction Manual

Hide thumbs Also See for SE 122:
Table of Contents

Advertisement

Available languages

Available languages

Appropriate extension cords are
available in special stores for electrical
equipment or from your STIHL dealer.
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
Plug the power cord or extension
N
cord into a properly installed outlet
SE 122, SE 122 E

Switching On

SE 122
Switch positions
Switch position 0 – vacuum cleaner is
switched off
Switch position I – vacuum cleaner is
switched on
To switch on, turn master switch to I
N
SE 122 E
auto
1
Power tools can be plugged into the
machine socket (1). Do not exceed the
maximum connected load of the
machine socket – see "Specifications".
Switch off the vacuum cleaner and
N
the electric power tool that is to be
connected prior to connection to the
machine socket (1).
The machine is switched on and off
N
or to automatic mode by means of
the switch (2). The suction power is
adjusted manually by turning the
switch.
Switch positions
Switch position 0 – Vacuum cleaner is
switched off, the socket outlet cannot be
used.
Switch position I – Vacuum cleaner is
switched on, the socket outlet cannot be
used.
Switch position auto – The power tool
connected to the machine socket
switches the vacuum cleaner on and off
via the automatic function.
The connected power tool must be
switched off before setting the master
switch to the "auto" position.
The motor runs on for a few seconds
after switching off in order to empty the
suction hose.
To switch on, set master switch to
N
0
I
the corresponding switch position