The Legend Brands DriTec 4000i desiccant dehumidifier reduces humidity in enclosed environments by
removing water vapour from the air. The 4000i is ideal for water damage restoration, structural drying,
construction, and is especially suited for removing moisture from structural materials and contents in
cold temperatures or low to medium humidity environments where refrigerant dehumidifiers work less
efficiently.
WARNING
Read and understand manual before operating.
WARNING! Do not alter or modify your DriTec in any
way. Use only replacement parts authorized by Leg-
end Brands. Modifications or use of unapproved
parts could create a hazard and will void your war-
ranty. Contact your local distributor for assistance.
WARNING! Electric shock hazard, rotating fan haz-
ard and hot surface hazards.
Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug
(not the cord) to unplug.
Must be earthed. Insert three-prong plug on
power cord into a matching electrically earthed
outlet. Do not use adapter. Never cut off third
prong. Do not use an extension cord.
The unit must be operated on a 230V/50 Hz cir-
cuit protected by a Residual Current Device
(RCD) device.
Keep motor and wiring dry.
Always unplug unit before cleaning or servic-
ing.
Do not attempt to repair the unit. For service,
contact your local distributor.
49-130B MANUAL, DRITEC 4000i 230V AU
Owner's Manual
4000i Desiccant Dehumidifier
Model F533-230V AU
LEGEND BRANDS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Patents: http://www.LBpatents.com
O R I G N A L I N S T R U C T I O N S
http://international.legendbrands.net
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by country/mar-
ket. Contact your local distributor for assistance. Regis-
tration allows us to better assist you with using, main-
taining or servicing your equipment and to contact you in
case we have important safety information concerning
your Legend Brands product. If you determine service is
required, have your equipment model, serial number and
original proof of purchase available and ask for assis-
tance with obtaining a return material authorization
(RMA).
GROUNDING INSTRUCTIONS
This unit's plug must be inserted into an appropriate out-
let that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs pro-
vided with the appliance – if the plugs do not fit the
outlets, have proper outlets installed by a qualified
electrician.
This equipment is for use on circuits with a nominal rat-
ing of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough treat-
ment can damage the unit, and may create a hazardous
condition or void the warranty.
This unit intended for household and commercial use.
1
Legend Brands, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DriTec 4000i and is the answer not in the manual?

Questions and answers

Summary of Contents for Dri-Eaz DriTec 4000i

  • Page 1 Phone: +1-800-932-3030 Fax: +1-360-757-7950 http://international.legendbrands.net The Legend Brands DriTec 4000i desiccant dehumidifier reduces humidity in enclosed environments by removing water vapour from the air. The 4000i is ideal for water damage restoration, structural drying, construction, and is especially suited for removing moisture from structural materials and contents in cold temperatures or low to medium humidity environments where refrigerant dehumidifiers work less efficiently.
  • Page 2: Before First Use

    2. Process air in duct (optional) 3. Place wire frame inside offset screws and click into place. When not in use, frame may be left in standoffs or placed in storage bin. 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 3: Control Panel

    Condensation may collect in the reactivation duct during opera- tion. Do not allow water to run back into the unit. This could cause a shock hazard or damage to the unit. 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 4: User Settings

    The following section available only on wireless-equipped units. SENSOR ID SENSOR TYPE SENSOR REVISION SENSOR CONF REV 000000000 > 00000 > 00000 > 00000 > (Returns to top menu item.) 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 5 Fig. C: Ducting Options 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 6: Transportation And Storage

    To remove the cable, first unclip the plug and then slide the cable down and out of the cable tie. Once the cable is free of the panel, set the panel aside. 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 7: Pump Purge Button

    Prompt to clean or change filter. Change or clean filter. Press XXXXX the > key to reset CLEAN ROTOR > Prompt to clean rotor. Clean rotor. Press the > key XXXXX to reset 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 8: Error Messages

    Key is stuck or has been held down too long. Contact service, ALL BUTTONS ER10 WIRELESS Wireless board has failed, Board is missing, shorted or has fallen off the control panel. CONNECTION ON BD Reinstall wireless board to clear error. Contact service. 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.
  • Page 9: Troubleshooting

    Dimensions (H × W × D) Contact your local distributor for assistance. 33.13 × 21.14 × 20.25 in. (With handle upright = 42.3 in.) Operating range -12.2–40.5°C | 10–105°F Air filter 3M HAF Safety 49-130B MANUAL, DRITEC 4000i 230V AU Legend Brands, Inc.