Page 1
New Product Electronic Thermostat Ideal for Simple Built-in Control. • A high switching capacity of 10 A at 250 VAC enables direct load switching. • A sensor is provided to enable immediate application. • Sockets with finger protection (PTF14A-E) or without finger protection (PTF14A) can be used.
Page 2
Ratings and Characteristics Ratings Item Model E5L-A@ E5L-C@ Power supply voltage 100 to 240 VAC, 50/60 Hz Operating voltage range 85% to 110% of the rated supply voltage Power consumption Approx. 3 VA Inputs Element-interchangeable thermistor Control method ON/OFF control Control output SPDT contacts, 250 VAC, 10 A, cosφ...
External Connections E5L-A@ E5L-C@ Control output Control output 250 VAC, 10 A 250 VAC, 10 A Element- Element- interchangeable interchangeable Thermistor Thermistor Input power supply: 100 to 240 VAC Input power supply: 100 to 240 VAC * Control output Heating load: Terminals 8 and 12 * Control outputs: Terminals 8 and 12 Cooling load: Terminals 4 and 12 Use the keys on the front panel to set direct/reverse operation.
Page 4
Measured temperature Tolerance −30 to 100°C ±2°C max. Measured temperature ±2% max. 100 to 200°C Mounting Brackets (Two) Temperature Sensors (Order Separately) E52-THE5A, E52-THE6D, and E52-THE6F Temperature Sensors can be ordered separately. For details, refer to an OMRON Web site.
Page 5
Operating the E5L-C@ Power ON Temperature Input Shift Direct/Reverse Setting Protection Operation Press the Press the Press the Press the Keys Keys for at least 3 s. for at least 3 s. for at least 1 s. for at least 1 s. Process value Set temperature Process value...
Page 6
Setting Protection 1. Setting Protection (Process Value Display) Press the Keys simultaneously while the process value is being displayed to change to the setting protection state. 2. Setting Protection (Set Temperature Display) From the Setting Protection (process value display) Mode, press Keys simultaneously to change to the setting protection (set temperature display) state.
Safety Precautions CAUTION Precautions for Safe Use Do not touch the terminals while power is being supplied. Be sure to observe the following precautions to prevent failure to Doing so may occasionally result in minor injury due to operate, malfunction, or adverse effects on the performance and electric shock.
Page 8
• Do not apply mechanical force to the temperature-sensing part of the thermistor. • The E52-THE@@ Thermistor can be used for applications that require metal protective tubing. Consult with your OMRON representative. Other Precautions • Do not use the E5L-C@ if the front sheet is peeling or torn.
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...