Download Print this page

Wiring Diagram - Whelen Engineering Company 295HFSA6 Installation Manual

Siren/power control center

Advertisement

UPPER CIRCUIT BOARD:
Fig. 3
NOTE: For access to circuit board S
RECOMENDED SIZE for CUSTOMER SUPPLIED WIRES:
Switch Power
10 AWG ........................................................................ 8 FT. MAX
8 AWG .......................................................................... 13 FT. MAX
6 AWG .......................................................................... 21 FT. MAX
Siren Power & Ground
12 AWG ........................................................................ 18 FT. MAX
10 AWG ........................................................................ 30 FT. MAX

WIRING DIAGRAM

1
1
20 AMP OUTPUT
2
2
20 AMP OUTPUT
3
3
4
20 AMP OUTPUT
5
11
6
10 AMP OUTPUT
10
7
10 AMP OUTPUT
12
8
10 AMP OUTPUT
8
9
10 AMP OUTPUT
7
10
BLACKOUT INPUT
3
11
BLACKOUT OUTPUT
6
12
10 AMP OUTPUT
9
13
BLACKOUT INPUT
2
14
BLACKOUT OUTPUT
5
15
10 AMP OUTPUT
1
4
10GA RED
10GA RED
BUTT SPLICES
CUSTOMER SUPPLIED 60 AMP FUSE / QTY. 2
Fuse, Jumper and Dip Switch Identification
ee Fig. 2 previous page
(AUX ENABLE)
TO HORN
HORN
BUTTON
WHITE / YELLOW
OPEN
WHITE / GREEN
RELAY
WHITE
GREY
YELLOW
YELLOW
ORANGE
BROWN
BLUE
ORANGE
BLUE
BROWN
VIOLET
BLACK
BLUE
BLACK
BLUE
RED
RED
VIOLET
BLACK
RED
CUSTOMER SUPPLIED 20 AMP FUSE
Rotary Switch Operations:
RAD (Radio Repeat) - When the rotary knob is in the RAD posi-
tion, any signal that is received by the vehicle's two-way radio will
be simultaneously broadcast over the vehicle's loudspeaker (the
295HFSA6 must be connected to the two-way radio as outlined in
this manual).
With the Rotary Switch in this Position:
Pressing the MAN switch will result in SiTest
(See SiTest section)
Pressing the HORN switch will result in the AIRHORN tone until
the HORN switch is released.
Activating the HORN RING input results in the AIRHORN tone
until the HORN RING input is released.
Activating the SIREN SHUTDOWN input has no effect.
Activating the AUX ENABLE input has no effect.
PA (Public Address) - When the rotary switch is in this position
the siren is in a standby state where no tones have been
activated, but is waiting for another action to be taken by the
operator. This position is often the best choice when public
address is required.
With the Rotary Switch in this Position:
.
Pressing the MAN switch will result in a WAIL tone ramping up
to the peak frequency and ramping down to a stop at the
lowest frequency when the MAN switch is released.
Pressing the HORN switch will result in the AIRHORN tone
until the HORN switch is released.
Activating the HORN RING input will result in the AIRHORN
tone until the HORN RING input is released.
Activating the SIREN SHUTDOWN input has no effect.
Activating the AUX ENABLE (Or slide switch position 3, if
selected) input will result in a repeating WAIL tone.
BACK LIGHTING
295HFSA6 Specifications
+12V
INPUT VOLTAGE . . . . . . . . . . . . . . . . . . . . . 12.5 VDC ±20%
INPUT CURRENT @15 VDC @ 5.5 OHMS . 16 AMPS MAX.
CUT
VEHICLE
WIRE
HORN
INPUT FUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 AMPS
HERE
SPEAKER IMPEDANCE. . . . . . . . . . . . . . . . 5.5 OHMS MIN.
11 OHM
SPEAKER #1
OPERATING TEMPERATURE . . . . . . . . . -30° C. TO +60° C.
STORAGE TEMPERATURE . . . . . . . . . . . -40° C. TO +70° C.
11 OHM
SPEAKER #2
HUMIDITY . . . . . . . . . . . . . . . . . 99% (NON CONDENSING)
TO TWO WAY
OUTPUT VOLTAGE @ 15 VDC @ 11 OHMS 32 V RMS MAX.
RADIO SPEAKER
OUTPUT POWER @ 15 VDC @ 11 OHMS 105 WATTS MAX.
SIREN SHUTDOWN
OUTPUT POWER @ 15 VDC @ 5.5 OHMS 185 WATTS MAX.
12 V
BATTERY
Page 7