Unitronics IO-LC1 Manual
Unitronics IO-LC1 Manual

Unitronics IO-LC1 Manual

I/o expansion modules 1-3 loadcell inputs, 1 digital in, 2 out
Hide thumbs Also See for IO-LC1:

Advertisement

IO-LC1, IO-LC3
The IO-LC1 and IO-LC3 are I/O
Expansion Modules that can be used in
conjunction with specific Unitronics OPLC
controllers.
IO-LC1 offers 1 Loadcell input; IO-LC3
module offers 3 Loadcell inputs. Both
modules offer 1 PNP (source) input and 2
short-circuit protected PNP (source)
outputs with optional setpoint action that is
defined via software settings.
The interface between the module and the
OPLC is provided by an adapter.
The module may either be snap-mounted
on a DIN rail, or screw-mounted onto a
mounting plate.
Component identification
1
Module-to-module connector
2
Communication status indicator
3
Power and I/O connection points
4
I/O connection points (IO-LC3 only)
5
Power and I/O status indicators
6
Module-to-module connector port
Before using this product, it is the responsibility of the user to read and understand this document and
any accompanying documentation.
All examples and diagrams shown herein are intended to aid understanding, and do not guarantee
operation. Unitronics accepts no responsibility for actual use of this product based on these examples.
Please dispose of this product in accordance with local and national standards and regulations.
Only qualified service personnel should open this device or carry out repairs.
User safety and equipment protection guidelines
This document is intended to aid trained and competent personnel in the installation of this equipment as
defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained
in the local and national electrical standards should perform tasks associated with the device's electrical wiring.
Symbols are used to highlight
information relating to the user's
personal safety and equipment
protection throughout this document.
When these symbols appear, the
associated information must be read
carefully and understood fully.
Failure to comply with appropriate safety guidelines can result in severe personal injury or
property damage. Always exercise proper caution when working with electrical equipment.
Unitronics Industrial Automation
I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out
Note: The single Loadcell input offered by IO-LC1 is marked
LC and is located where the input LC2 is shown above.
Symbol
Meaning
Danger
Warning
Caution
Caution
Description
The identified danger causes physical
and property damage.
The identified danger can cause
physical and property damage.
Use caution.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IO-LC1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Unitronics IO-LC1

  • Page 1 All examples and diagrams shown herein are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product in accordance with local and national standards and regulations.
  • Page 2: Environmental Considerations

    Do not allow debris to fall inside the unit during installation. Mounting the Module DIN-rail mounting Snap the device onto the DIN rail as shown below; the module will be squarely situated on the DIN rail. 80mm (3.15") Unitronics Industrial Automation...
  • Page 3: Screw-Mounting

    Screw-Mounting The figure below is not drawn to scale. It may be used as a guide for screw-mounting the module. Mounting screw type: either M3 or NC6-32. 80mm (3.15") 5.8mm 68.4mm (0.228") (2.693") (0.16") 4mm (x2) (0.16") Unitronics Industrial Automation...
  • Page 4: Connecting Expansion Modules

    Input or output cables should not be run through the same multi-core cable or share the same wire. Allow for voltage drop and noise interference with input lines used over an extended distance. Use wire that is properly sized for the load. Unitronics Industrial Automation...
  • Page 5: External Power Supply

    I / O E x p a n s i o n M o d u l e s External Power Supply All of the IO-LC1, IO-LC3 I/O signals are isolated from the controller bus, but are not isolated from the power supply input. If required, you can provide full isolation by using a separate isolated power-supply.
  • Page 6 The cable shield should be connected ONLY to the Loadcell chassis. The shield at the other end of the cable should be left unconnected. Refer to the figures below for wiring guidelines. 6 wire Loadcell wiring 4 wire Loadcell wiring Unitronics Industrial Automation...
  • Page 7 —Lit when a communication link is established between module and OPLC. —Blinks when the communication link fails. Loadcell Inputs Number of inputs 3 for IO-LC3, 1 for IO-LC1 Galvanic isolation Loadcell to ext. pwr supply Loadcell to bus Loadcell to digital input...
  • Page 8 Green LED—Lit when the input is active. See Note 5. (IN) Digital Outputs Number of outputs 2 pnp (source) Output type P-MOSFET (open drain) Galvanic isolation Dig. output to ext. pwr supply Dig. output to bus Dig. output to Loadcell Dig. output to digital input Unitronics Industrial Automation...
  • Page 9 AC excitation has the advantage of lower offset drift errors, improving performance over time and in the presence of ambient temperature changes. To minimize the impact of offset drift errors in your loadcell application, the use of AC excitation is recommended. Unitronics Industrial Automation...
  • Page 10: Effective Resolution

    The number of Loadcell inputs used per expansion module affects the sampling rate for each of them, resulting in lower filter depth and effective resolution. The filter settling time can be programmed separately for each Loadcell input without affecting the other(s). Unitronics Industrial Automation...
  • Page 11 RO8 is always assigned the number 7. Its I/Os are addressed accordingly. Example Input #5, located on an EX90-DI8-RO8 connected to an OPLC will be addressed as I 149, 149 = 32 + 7 • 16 + 5 Unitronics Industrial Automation...
  • Page 12 Unitronics products referred to herein in any manner deviating from the recommendations made in this document. Unitronics assumes no responsibility for the use of any parts, components, or other ancillary appliances including circuitry other than as recommended hereunder or other than that embodied in the Unitronics product.

This manual is also suitable for:

Io-lc3