Lyngdorf products and accessories comply with parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; and (2) this device must accept any interference received, including any interference that may cause undesired operation.
This is referred to as POST PROCESSING, and it can be set on a Source or controlled from your remote control. New on the MP-60 is the DTS Virtual:X, which can create a virtual surround sound experience from a simple stereo setup.
It should be placed in an environment free of excessive heat. • In a rack system, the MP-60 should be placed at the bottom of the rack, still with at least one inch / 25mm free space on top and sides.
TCP connection. If you do not know the IP address of the MP-60 on your local network, the MP-60 supports Apple´s Bonjour Discovery service, which must be on the computer with which you wish to set up the MP-60. The software is built-in as part of the Apple OS X operating system (not iOS devices).
Rear Panel On the back of the MP-60, you will find a range of inputs and outputs: • 16 x XLR, Differential balanced audio outputs (configured for 11.1 plus 4 auxiliary) • 8 x HDMI inputs and 2 x HDMI outputs, all 4K / 18 Gbps compatible. eARC on HDMI 1 •...
Remote Control The MP-60 comes with a dedicated remote control, which can operate both with radio frequencies (RF) and infrared control (IR) Setup Access the installation menu. Standby Turn the MP-60 on and into standby. Audio Access the post-processing menu.
2. Hold down Play/Pause and OK until the remote control´s green LED flashes. 3. Release the buttons. 4. Point the remote control at the MP-60 and hold it within 30cm / 1 foot of the front panel; when the green LED stops blinking, the remote is connected.
13. Save and make a backup of the calibration and settings. Installation Via Installer Menu Connect a screen to the MP-60 using any of the video output sockets on the back. Access the menu system by pressing the Setup button on the remote control.
This page shows information as to audio and video inputs and formats, and you can control the volume level or Mute the sound. These settings will be reset to default values, when the MP-60 is turned into stand-by mode.
Page 13
The interface for controlling the built-in media streamer is found in the bottom section of this page. For information as to the use of the interface see section for Streaming Setup. Lyngdorf Audio MP-60 – Owner’s manual...
Select the audio input connector. If you want the audio input to match the video input from an HDMI source, select HDMI Audio. If you want to create a Source using the built-in radio player, you should choose Internal Player, which will activate the selection of Preset vTuner stations. Lyngdorf Audio MP-60 – Owner’s manual...
Page 15
Delete Source Delete an enabled source through Screen Setup by highlighting it and pressing right on the remote. In the web menu press Delete button. Lyngdorf Audio MP-60 – Owner’s manual...
Speakers and Room You need to configure the MP-60 according to your speaker setup, setting the sizes of the speakers, so that the Bass Management function can optimize the overall performance. In the setup page the connectors will be highlighted with information as to signal type.
Page 17
Right top middle Left top rear Right top rear Speakers designated according to AURO 3D specifications: Height left Height right Height left surround Height right surround Height center Top ceiling / Voice of God Lyngdorf Audio MP-60 – Owner’s manual...
Page 18
The MP-60 can decode up to 16 channels (including the LFE, Low Frequencies Effects), and the system will inform you, if you try to activate more speakers than the MP-60 can process – or is trying to make a setup, which cannot be handled due to the limitations set by Dolby, DTS or Auro.
Page 19
3-dimensional sound field. Note: If you set the Center speaker to ‘None’, the MP-60 will automatically route the dialogue from the center channel into the Left and Right speakers.
Page 20
This function refers to a setup, where the front and/or side speakers are with an up-firing speaker to imitate a ceiling speaker. Dedicated speakers for this purpose will feature a cue filter, and these channels will not be included in the RoomPerfect™ calibration. Lyngdorf Audio MP-60 – Owner’s manual...
Page 21
Amplifier Delay If your subwoofer features internal processing, you need to compensate for this by entering the relevant delay in milli-seconds. Lyngdorf Audio MP-60 – Owner’s manual...
Page 22
With one or more active subwoofer(s) connected to the MP-60, this menu will guide you into setting the volume level on each subwoofer’s controls. Follow the instructions on the display to go through two phases: 1.
When measuring distances to in-wall woofers: • If the stack of woofers is taller than the listening position, measure the distance from the listening position to the dust cap of the middle of the stack of woofers. Lyngdorf Audio MP-60 – Owner’s manual...
The RoomPerfect™ microphone is a very sensitive and finely calibrated device which must be treated with utmost care. If the microphone has been dropped on the floor, it may be damaged. If this is the case, obtain a new microphone from your Lyngdorf Audio representative before performing the system calibration.
Keep taking measurements until RoomKnowledge reaches minimum 90%. These are the rules of thumb when measuring the room: • the microphone should be in random and varying positions, heights, and orientations. Point it up/down/sideways, the more random positions the better. Lyngdorf Audio MP-60 – Owner’s manual...
• do not take symmetrical measurements in the room. Top view of room Room Measurements Above 90% RoomKnowledge When RoomKnowledge has reached 90%, you can decide to add room measurements or do it later. Lyngdorf Audio MP-60 – Owner’s manual...
Page 27
Calculation of Focus and Global Filters When room measurements are complete, the system will calculate the focus and global filters automatically. Note: We recommend that you ALWAYS make a backup of the MP-60 settings and calibration data after having performed a RoomPerfect™ calibration (see Manage Software in the Setup section).
Set the RoomPerfect™ bypass mode for your device to Off or On. Enable front IR sensor Turn the MP-60´s IR sensor Off or On. This function is useful if you are using a home automation system and other remotes are using the same IR codes as the MP-60 remote.
The MP-60 will turn on if a voltage above 1.5V is detected. Trigger Out Setup Allows you to set up the system so that the MP-60 can control the power state of other devices like amplifiers and curtains through a simple connection.
The MP-60 can access music files on your local network or on a FAT32 formatted storage device connected to any of the USB A inputs, and you can stream music to the MP-60 from your mobile devices. In this menu you can configure the basic setup of the music streaming: •...
Page 31
When a station or podcast is playing, you can assign it to one of the 4 ‘select save-position’. The saved stations can as presets be assigned to a SOURCE for direct selection, if you as ‘audio input’ select ‘Internal Player’ (see menu: SETUP/SOURCE). Lyngdorf Audio MP-60 – Owner’s manual...
Video Setup The Video Setup menu allows you to register the video system settings for the MP-60’s video inputs and outputs, which in turn dictates which video formats can be shown on the screen when these inputs and outputs are activated.
Page 33
The television is the Master of this communication and is informing all sources of what signal types, it can receive. The MP-60 is a HDMI Repeater, and will correct the EDID information sent to the sources, if you have changed any of the settings.
This output can output a digital, stereo audio signal, which you can use as input for a system in adjacent rooms. The MP-60 can decode one HDMI source only and selecting ‘Follow Main’ will output a stereo downmix of the movie in the main room. The output does not hold any RoomPerfect™ filters.
This file can also be used to move the entire setup to another MP-60 processor – and it can be included in communications as to setup issues.
Page 36
Update Software Update from Remote Files When connected to the Internet, the MP-60 will automatically identify new software updates from our server. 1. Select the file listed on the remote server list. 2. Press Start Update to upload the new software to the MP-60.
• Check the measuring signal volume. If none of these measures solve the error, request a replacement microphone from Lyngdorf Audio. Fault – Signal clipping Either the incoming signal has been classified as too loud, resulting in clipping or distortion, or a loud noise in the immediate environment has corrupted the measurement results.
Page 38
• The MP-60 needs to be set to Network mode to be able to turn on via a control system. It will not turn on when in Deep Sleep. This is set up in System Configuration / General Setup/ Power Management...
Furthermore, the Mode option in the Network Setup menu must be set to Manual IP. Finally, you must manually set an IP address on the computer you intend to use for setting up the MP-60.
Page 40
Click Use the following IP address and enter the following: IP address: 192.168.1.2 Subnet mask: 255.255.255.0 Default gateway: 192.168.1.1 Click OK to close the configuration windows, and you should now be able to access the MP-60 via your Internet browser. Lyngdorf Audio MP-60 – Owner’s manual...
Page 41
Click Use the Following IP address and enter the following: IP address: 192.168.1.2 Subnet mask: 255.255.255.0 Default gateway: 192.168.1.1 Click OK to close the configuration windows, and you should now be able to access the MP-60 via your Internet browser. Lyngdorf Audio MP-60 – Owner’s manual...
HDBaseT™ and the HDBaseT Alliance logo are trademarks of the HDBaseT Alliance. Service Information In order to obtain warranty service, you must contact your original dealer or the Lyngdorf Audio distributor of the region or country where you are located.
Need help?
Do you have a question about the MP-60 and is the answer not in the manual?
Questions and answers