Important safety instructions! Please read before connection!
DANGER! (Electric shock due to high voltages in the device)
The housing must not be removed! There are no parts to be maintained in the device.
Inside the unit there are components which are under high electrical voltage.
Before each use, check the device for damage or the absence of components, protective
devices or housing parts. If this is the case, do not use the device!
Leave maintenance and repair work to a qualified service workshop or contact your
dealer.
DANGER! (Electric shock due to short circuit)
Modifications to the power cord or plug are prohibited. If the power cord is damaged, it
must be replaced immediately with an original spare part from the manufacturer. Failure
to do so may result in fire or death due to electric shock!
DANGER! (For babies and children)
Dispose of or store any packaging material properly! Packaging material must be kept out
of the reach of babies and children due to the danger of suffocation.
Make sure that children never use the device unattended! In addition, make sure that
children do not remove (small) parts from the device, as they could suffocate by
swallowing parts!
Hint! (Fire hazard due to overheating)
The maximum permissible ambient temperature of this device is 40°C.
Ensure that the unit is placed in a place with adequate ventilation, out of the reach of
direct heat sources, naked flames and combustible materials and liquids.
The ventilation slots of the device must not be taped or covered.
Hint! (Operating conditions)
Due to its structural characteristics, the device is designed for indoor operation (IP20).
Never expose the device to rain, moisture or liquids as this may cause damage.
Vibrations, dust or solar radiation can also lead to damage, avoid them!
Hint! (Condensation)
To avoid condensation in the unit, the unit should adapt to the ambient temperature
before commissioning.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CM2 and is the answer not in the manual?

Questions and answers

Summary of Contents for FAME CM2

  • Page 1 ENGLISH Important safety instructions! Please read before connection! DANGER! (Electric shock due to high voltages in the device) The housing must not be removed! There are no parts to be maintained in the device. Inside the unit there are components which are under high electrical voltage. Before each use, check the device for damage or the absence of components, protective devices or housing parts.
  • Page 2 ENGLISH Hint! (Power supply) This large diaphragm condenser microphone is operated with phantom power. According to DIN 45596, phantom power is a positive voltage of 12, 24 or 48 volts on both AF lines compared to the cable shielding. The phantom power usually comes from mixing consoles, sound cards or microphone amplifiers, sometimes also from batteries.
  • Page 3 ENGLISH Symbols on device and packaging: The lightning flash symbol warns the user about non-insulated current and the risk of electrocution. The exclamation mark symbol warns the user about important maintenance and operating instructions in the manual. The lightning warns you of dangerous voltage accessible from the outside. A connection to any terminal marked with this symbol may only be made with a ready-made cable that complies with the manufacturer's recommendations or with cables installed by qualified personnel...
  • Page 4: Intended Use

    Intended use: The product FAME Studio CM2 was designed for use as a microphone. The device may only be operated for this purpose and in accordance with the operating instructions. Other purposes as well as operation under other operating conditions are expressly not intended and can lead to damage to property or personal injury! No liability is assumed for damage resulting from improper use.
  • Page 5: Installation

    Equipment and use: This large diaphragm condenser microphone has a three-pin XLR connector and comes with a matching bracket. Due to its characteristics, the FAME CM2 can be used for miking vocals, acoustic instruments or percussion. Commissioning: All connections of the device should be made before switching on.
  • Page 6: Directional Characteristics

    Sound hitting the rear is suppressed or damped by the cardioid characteristic. The focus here is on the direct signal. FAME CM2 – Cardioid characteristic: The included USB condenser microphone features a cardioid characteristic that effectively cancels or attenuates sound from the rear (at 180° or below). This microphone is therefore ideal for voice, vocal, voice-over and instrument pickups.
  • Page 7: Specifications

    ENGLISH Specifications: Model FAME CM2 Sound conversion principle Condenser microphone Diaphragm size 1 inch large diaphragm Directional characteristic Cardioid characteristic Frequency range 20 Hz – 20 kHz Field transmission factor 7 mV / Pa (bei 1 kHz) Output impedance 200 Ohm...
  • Page 8: Environmental Protection

    ENGLISH Cleaning: A regular cleaning of the device from impurities and dust increases the durability of the product. Always disconnect the device from the power supply before cleaning it! Never clean the appliance wet! Optical lenses should be cleaned with a dry microfiber cloth to optimize light output. Ventilation grilles and openings should always be cleaned of dust and dirt.