TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Unit
Temperature Sensor Control Register
MF_TEMPSENSE_CTRL
Temperature Sensor Control Register
31
15
RES
r
Field
RES
RES
SYS_OT_STS
SYS_OTWARN_STS
LS_OT_STS
LS_OTWARN_STS
RES
Table 363 RESET of
MF_TEMPSENSE_CTRL
Register Reset Type
RESET_TYPE_4
User Manual
10
9
RES
r
Bits
Type
31:10
r
9:8
r
7
r
6
r
5
r
4
r
3:0
r
Reset Values
Reset Short Name
00000003
RESET_TYPE_4
H
Offset
10
H
RES
r
8
7 7
6 6
5 5
SYS_
SYS_
LS_O
OT_*
OTW*
T_S*
r
r
r
Description
Reserved
Always read as 0
Reserved
Always read as 0
System Overtemperature (MU) Status
0
INACTIVE, write clears status
B
1
ACTIVE, interrupt status set
B
System Overtemperature Warning (MU) Status
0
INACTIVE, write clears status
B
1
ACTIVE, interrupt status set
B
Low Side Overtemperature (MU) Status
0
INACTIVE, write clears status
B
1
ACTIVE, interrupt status set
B
Low Side Overtemperature Warning (MU) Status
0
INACTIVE, write clears status
B
1
ACTIVE, interrupt status set
B
Reserved
Always read as 0
Reset Mode
686
Reset Value
see
Table 363
4 4
3
LS_O
RES
TWA*
r
r
Note
16