Table of contents Table of contents Safety ......................... Presentation of warning signs ......................Intended purpose of use ........................ General safety and accident prevention regulations ..............1.3.1 Intervention rules on sites ......................State of technology......................... Personal protective equipment ....................... Spare parts and liability ........................Security inspection according EN 16005 ............
Page 3
Table of contents Description......................General view ..........................Safety equipment and operating elements ..................4.2.1 Opening and security sensors (combined) ..................4.2.2 Collision detection .......................... 4.2.3 Security sensors side panel ......................Components of the system ......................Technical data ....................Operation ......................Selection of operating modes (BDE-D) ..................
Page 4
Table of contents 8.3.2 Manual closing - Step 2 ........................Operating door in emergency ......................8.4.1 Emergency opening with current supply ..................8.4.2 Emergency opening in case of power failure with a back-up battery (optional)......8.4.3 Emergency operating using Bowden cable (Option) ..............Taking out of service and disposal ..............
Safety Safety Presentation of warning signs Various symbols are used in this guide for easier understanding: NOTICE Useful advice and information to ensure correct and efficient workflow of the system. IMPORTANT Specific details which are essential for trouble-free operation of the sys- tem.
Safety General safety and accident prevention regulations NOTICE If necessary, the country specific regulations have to be adhered to. NOTICE This system is not intended to be used by persons (including children from the age of 8) with limited physical, sensory or mental abilities or with a lack of experience and/or knowledge.
Safety CAUTION Unexpected OPENING / CLOSING / ROTATION • Bruises and contusions from the door wings/apron No persons or objects are allowed in the opening area of the door. No safety devices (sensors) should be removed or disabled. ...
Safety NOTICE Ensure regularly that all safety systems are in good working order. State of technology This system was developed using state of the art technology and officially recognized technical safety regulations. The system, depending on its options and diameter, comply with the requirements of the Machine Guidelines 2006/42/EG as well as EN 16005 and DIN 18650 (D).
Safety Safety shoes protect the feet from crushing, falling parts and slipping on surfaces. The puncture resistance of the shoes ensures, that pointy objects do not penetrate the foot. The high-visibility vest is used to make the personnel stand out and therefore to be seen.
Security inspection according EN 16005 Security inspection according EN 16005 Like the German standard DIN 18650, the EN 16005 describes the requirements and the test me- thods for the safe use of power-operated pedestrian doors. The EN 16361 describes the require- ments for the production process and documentation / classification of the doors.
Security inspection according EN 16005 Term according to DIN Description EN 16005 Main closing edge Edge of a door wing, whose distance from the parallel opposing closing edge or opposing surface determines the usable open width. Opposing / counter clo- Closing edge formed by the main closing edge of opposing closing wing, a sing edge fixed edge or a surface, against which the wing moves (i.e.
Security inspection according EN 16005 2.3.1 DIN aluminium finishing profiles Solution: ▪ DIN aluminium finishing profiles + safety distances ▪ DIN aluminium finishing profiles See Book B1 „General Information“ Chapter „General Plans“ Example D-STA 32 mm with side screen and cladding Version DIN aluminium finishing profiles (P1752) Version rubber finishing profiles (P1760) NOTICE The version with rubber finishing profiles is not EN 16005 compliant with...
Security inspection according EN 16005 If S ≤ 8 mm then t ≤ 0 mm S ≤ 8 mm → Y ≤ 0 mm If S > 8 mm then t ≥ 25 mm S > 8 mm → Y ≥ 25 mm Figure b) Shearing and drawing-in protection Figure d) Finger protection (drawing-in) 2.3.3...
Security inspection according EN 16005 2.4.2 Additional requirements for doorsets in escape routes and emergency exits When an operating mode selector is used, the mode of operation shall be clearly identified and marked on the operating mode selector. If a "locked" mode of operation is available, the mode of operation shall be protected, e.g. by an ac- cess code or a key, so that changes can only be made by authorised personnel.
General information General information Purpose and use of the instructions These instructions are an integral part of the system and enable efficient and safe handling of the sys- tem. In order to ensure proper functioning, the instructions must be accessible at all times and kept in the immediate area of the system.
General information Target groups This operating manual is intended for the target groups listed below: ▪ Operating entity of the system: the person who is responsible for the technical maintenance of this system ▪ Operator of the system: the person who operates the system every day and has been suitably instructed General definitions of terms The following terms are used in manuals for easier understanding: Term:...
Description Safety equipment and operating elements Pos. Components Pos. Components Trigger and safety sensor / combinati- Key switch BDE-V (option) on sensor (inside and outside) Control unit BDE-D Manual release 4.2.1 Opening and security sensors (combined) Each passage area is monitored with opening and security sensors. If an opening or security sensor is activated during the closing process while in AUTOMATIC or ONEWAY TRAFFIC operating mode, then the respective sliding door will re-open/reverse again.
Operation Technical data NOTICE The power connection must be installed by a licensed electrician. The power must be able to be shut off via a main switch or residual current circuit breaker (on-site). NOTICE For underfloor drives, an FI should be installed by the customer. Description Designation Underfloor sliding door system (complete door s.) S20 SU...
Operation Operation Selection of operating modes (BDE-D) The electronic control unit BDE-D is a user-friendly input/output module to control and customise (op- tional) the system operation. The backlit LCD display informs about the system status by means of symbols and plain text. Error messages are displayed as text. Button Operating Symbol dis-...
Operation Selection of operating modes (RED) The electronic control unit BDE-D is a user-friendly input and output unit to control and customise (op- tional) the door operation. The LCD display with backlight gives information about the door status with symbols and clear text. Error messages are displayed as text. Control unit BDE-D ▪...
Operation ▪ Door opens unhin- dered from inside or Reduced opening width outside ▪ Reduced opening width (winter ope- ning) ▪ Reduced opening width is set to the minimum authorised value according to country-specific gui- delines and cannot be further diminis- hed via BDE-D NOTICE The reduced opening width is also effective with operating modes...
Operation Operating mode Function Automatic mode with total This operating mode is the standard operating mode. opening width Through triggering of a e.g. Radar, the door opens. After the pre-set door time delay, the door closes. Continuously open and manual Door opens and stays in open position.
Operation NOTICE The installation remains in the mode of operation previously selected Locking the control unit with a key (option) IMPORTANT Standard EN 16005 requires protection, for the mode selection of operation of pedestrian automatic doors, used as emergency exits so that they may not be inadvertently locked when the building is in use.
Servicing and maintenance Servicing and maintenance General remarks According to the legal provision in force, the operating entity of the automatic door is responsible for its maintenance and for the user's safety, as soon as the installation has been handed over. The regular inspection of single elements by the operator requires little time investment and reinforces the prevention of accidents caused by an inappropriate use of the door.
Servicing and maintenance Monthly inspection work to be carried out by the operating company The monthly inspection and maintenance of individual elements by the operating company requires little time and serves the reliable function, increased service life and operational safety of the system. Test / inspection Procedure Expected result...
Page 27
Servicing and maintenance Test / inspection Procedure Expected result ▪ Set the door to manual ope- ▪ The door leaf must be pro- Continuous floor guide (instead of punctual door leaf guide) ration (see chapter "Selecting perly guided ▪ The movement of the door special functions") ▪...
Malfunctions Malfunctions Behavior in event of faults In the event of an irregularity or malfunction, different displays are shown depending on the control unit connected. IMPORTANT If malfunctions that endanger the safety of individuals occur, the system must be turned off. It may not be turned back on until the problem has been resolved by a professional and the danger no long exists.
Malfunctions 8.1.4 Control unit BDE-D does not react If the control panel does not react when the keys are pressed or if no message appears on the dis- play, a reset of the control panel could eliminate the problem. Proceed as follows: RESET HARDWARE BDE-D Press E key >...
Malfunctions Manual closing Initial situation: Electric power is supplied. Door remains blocked in open position. NOTICE Depending on the kind of failure, the procedure for a manual closing will be diffe- rent. Please follow the steps described below. 8.3.1 Manual closing - step 1 Function Display Description...
Malfunctions ▪ Push the door manually into the closed positi- ▪ Actuate the release lever clockwise until the locking bolt releases and locks the door. ▪ Check by hand whether the door is really lo- cked. ▪ Leaving the building only possible via a se- cond exit Call service station (phone number shown on display)
Page 32
Malfunctions 8.4.3.2 Procedure for an emergency opening Emergency opening ▪ Open the unlocking flap ▪ Pulling the unlocking flap downwards unlocks the door ▪ Display on the BDE-D → Error No. 31 / Emergency stop ▪ The door can be slid open by hand 8.4.3.3 Closing and locking the door ▪...
All machine parts must be sorted by type of material and disposed of according to local regulations and guidelines. NOTICE The record door systems can be completely disassembled in reverse order. The automatic door mainly consists of the following materials: Aluminum: ▪...
Page 34
Contact record UK limited Head Office: Unit D, 9 Watt Place - Hamilton International Park - Blantyre - G72 0AH - UK Central Office: Batley Business Centre - Unit 40 - Annexe 2 - Technology Drive - Batley - Wf17 6ER - UK Southern Office: 17 Invincible Road - Farnborough - Gu14 7QU - UK tel.: +44 1698 376411 - fax: +44 1698 376422 -...