Field Replacement Procedure
Unity All Flash and Unity Hybrid Field Replacement Procedure
10
Service Password
Serial Number
Site ID
OE version
2. Using an SSH/Telnet client, such as PuTTY, type the system IP address and
login as the service user.
3. Put both SPs in Service Mode and power off the system:
Issue both of these commands to each SP.
svc_rescue_state -s
svc_shutdown --halt-local
Note
This process can take between 10 and 20 minutes to complete. During this time,
the connection to the system will be lost and you will not have access to
Unisphere or the online help.
4. Wait until the SP fault LEDs on both storage processors are flashing alternating
amber and blue before continuing to the next task.
The SP fault LED flashes alternating amber and blue while the SP remains in
Service mode and is receiving active power.
Figure 2 SP fault LED
1 GbE
1 GbE
2
2
3
3
MAC:
MAC:
1
1
0
0
1
1
10 GbE
10 GbE
x4
x4
x4
x4
5
5
4
4
Need help?
Do you have a question about the Unity Series and is the answer not in the manual?
Questions and answers