Installation

Installation Requirements
TRION'
Locate the air cleaner in the return air duct next to the
TYPICAL INSTALLATION
RIGHT ANGL
blower compartment. In this location, the blower motor
and the cooling coils will be kept clean. Do not install the
air cleaner in the discharge air duct. Do not install the air
cleaner where it is directly exposed to UV Lighting. The
unit must be readily accessible for periodic inspection and
replacement of the filter cartridge to maintain maximum
efficiency and trouble-free operation. A clean coil will
reduce utility cost by maintaining the coil's efficiency.
Failure to replace the filter cartridge can cause damage to
the cooling system. Allow a minimum of 30" clearance in
front of the access panel for filter cartridge replacement.
AIR B
Air Cleaner Installation and Maintenance
RIGHT
TRION'S AIR BEAR
®
The right angle media air cleaner has been designed
SPACE
TYPICAL INSTALLATION
RIGHT ANGLE INSTALLATION
Smaller
specifically for highboy furnaces with direct installation to
the heating and cooling system return air duct.
The duct opening of the air cleaner is supplied with an
adjustable inlet flange.
The unit is shipped with the flange set at 24"x 8". If the
incoming duct is 24"x 8", attach the duct directly to the
flange and secure with sheet metal screws through the
pre-drilled holes.
If the flange requires adjustment to 24"x 10", remove
AIR BEAR
®
the five #6 sheet metal screws securing the flange to
RIGHT ANGLE
the cabinet. Adjust flange to 24" x 10" and secure with
SPACE SAVER
screws. Proceed with installation.
Smaller Footprint!
Select Location for the Air Cleaner
Select a location that is readily accessible for periodic inspection and cleaning. Allow
a minimum of 30" in front of the access panel for filter removal.
Direction of Airflow through the Air Cleaner
Note: The air cleaner is designed for easy access from
either side. Select the location and locate air cleaner
opening next to furnace. Install the door handle on the
front panel to allow easy access for filter cartridge removal.
The direction arrow on the filter cartridge must point in the
direction of air flow.
Mounting holes are provided in the air cleaner cabinet for
duct work attachment. The .187" holes are sized for #8
sheet metal screws or 1/8" rivets.
w w w. t r i o n i a q . c o m
3
A i r B e a r
R i g h t A n g l e
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Air Bear Right Angle Supreme MERV 8 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Air bear right angle supreme merv 11Air bear right angle supreme merv 13Air bear right angle supreme-hd merv 8Air bear right angle supreme-hd merv 11Air bear right angle supreme-hd merv 13447380-010 ... Show all

Table of Contents