Advertisement

Palintest
®
Pooltest 9
luetooth
®
Operation
anual
Palintest
®
ZI INST 7009B EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pooltest 9 Bluetooth and is the answer not in the manual?

Questions and answers

Summary of Contents for palintest Pooltest 9 Bluetooth

  • Page 1: Appendix

    Palintest ® Pooltest 9 luetooth ® Operation anual Palintest ® ZI INST 7009B EN...
  • Page 2: Appendix

    Our products are used in a wide variety of applications to protect the environment and safeguard public health. To find out more about Palintest please visit www.palintest.com or contact your local Palintest partner. Palintest is a registered trademark of Palintest Ltd.
  • Page 3: Table Of Contents

    Introduction Analysing Samples Selecting Test Parameters Dilution Factor Quick Start Blanking Pooltest 9 Bluetooth Pooltest 9 Layout Reading with the Pooltest 9 Bluetooth Pooltest 9 Interface Timer Info Panel Changing Result Units of Expression Follow-on Tests Taking a Sample Test Methods...
  • Page 4: Introduction

    The Pooltest 9 Bluetooth offers a choice The fundamental operating technique applied to of connectivity to download all or selected the Pooltest 9 Bluetooth is based on the principles results via Bluetooth 4.0 wireless connectivity of optical absorbance and scattering of visible light.
  • Page 5: Quick Start

    Quick Start 2.0 Quick Start 2.1 Pooltest 9 Bluetooth Layout USB Port Light Cap Adaptive Cuvette Holder (do not insert finger!) On/Off LCD screen with backlight Numerical keys Navigation for test selection Keys and text entry 2.2 Pooltest 9 Interface 2 Dialogue screen - prompts and choices will be displayed as a list.
  • Page 6: Taking A Sample

    Taking a Sample 3.0 Taking a Sample The first critical step in any analysis is taking a • Rinse any sample container repeatedly with representative sample. When selecting a sample the sample to prevent any cross contamination point a number of care points are recommended from previous samples as follows: •...
  • Page 7: Starting Up The Instrument

    To access the Mode menu press the left arrow key to highlight ‘Back’ and press OK on the keypad. The Pooltest 9 Bluetooth is designed to be powered To choose a test use the up/down arrows to scroll either from alkaline batteries or via the USB port.
  • Page 8: System Mode

    5.2 Operator ID automatically overwrites the oldest result when the memory is full. The data log is unaffected by The Pooltest 9 Bluetooth offers the option to create power on/off. up to 12 unique alphanumeric Operator IDs. Operator Each data point consists of the following...
  • Page 9: Sample Id

    After entering a character, the cursor automatically 5.3 Sample ID moves to the next position if no key is pressed. The Pooltest 9 Bluetooth offers the option to create Alternatively press the right key. up to 24 unique alphanumeric Sample IDs. Sample...
  • Page 10: Bluetooth

    Palintest Portal. mobile device. The Pooltest 9 Bluetooth will validate the paired connection and confirm readiness to transfer. There are four options available in the Bluetooth menu: • Bluetooth Communications ON - activate the Bluetooth and make the Pooltest 9 Bluetooth visible for connection/pairing.
  • Page 11: Usb Interface

    • Log.txt - the data log file stored in a comma separated value (csv) format If the connection is lost the Pooltest 9 Bluetooth will prompt for re-connection. If connection is not required or possible press Exit to disable Bluetooth and cancel the log transfer.
  • Page 12: Units

    This allows backwards compatibility with software 5.8 DPD Range written for earlier models of Palintest instruments. The Pooltest 9 Bluetooth operates in a choice of DPD In this mode, the PC requires installation of ranges, depending on the pool treatment programme.
  • Page 13: Temperature

    System Mode 5.11 Temperature Press OK when the correct date is set. Choose between ºC and ºF. The temperature setting The Date Format can be set to DD/MM/YYYY or is used during the Langelier Saturation Index when MM/DD/YYYY as required. To select the required selected from the Water Balance option.
  • Page 14: Lcd Contrast

    System Mode 5.16 LCD Contrast 5.17 Version In addition to the Backlight, the default contrast The serial number of the instrument and the setting for the display can be adjusted using the software version are displayed. The instrument up/down keys when light conditions are difficult. serial number will be required for technical support and servicing/warranty and can also The display provides a sequence of alternating...
  • Page 15: Analysing Samples

    When a test is selected, the Pooltest 9 Bluetooth test instructions. will display a number of screens and options to The principle of photometric testing is based on the...
  • Page 16: Reading With The Pooltest 9 Bluetooth

    Blank results are stored in the temporary memory of the Pooltest 9 Bluetooth and will be used for all subsequent tests until: • The instrument is powered down (temporary memory is lost/deleted) •...
  • Page 17: Timer

    At the Insert sample prompt, insert the sample to develop, the recommended time period being cuvette ensuring it is clean and dry and oriented documented in the Palintest Phot Book and included correctly using the location mark. as part of the method parameters programmed into the Pooltest 9 Bluetooth.
  • Page 18: Follow-On Tests

    Analysing Samples Phot 007 Free Chlorine. Follow-on methods are usually either based on further reagent addition to the sample just measured for sequential parameters or used to correct for potential/known interferences. Follow-on tests are clearly defined in the Section 8 and, if available, are accessed via the Follow-on option located at the right hand side of the options.
  • Page 19: Test Methods

    Test Methods 7.0 Test Methods The Pooltest 9 Bluetooth provides simple test Test 1 Chlorine-Free/5 or Chlorine-Free/10 protocols for the key parameters required to Standard Range: 0-5.00mg/l (ppm) Cl (use DPD 1) effectively control swimming pools, hydrotherapy Extended Range: 0-10.0mg/l (ppm) Cl (use DPD XF) pools, spas and hot tubs.
  • Page 20 Test Methods Test 3 Bromine Test 5 Copper-Total/5 Range: 0-10.0mg/l (ppm) Br Range: 0-5.00mg/l (ppm) Cu Colour change: Colourless - Purple/Red Colour change: Colourless - Purple 1 Rinse test cuvette with sample leaving 1 Fill test cuvette with sample to the 10ml mark. two to three drops in the tube.
  • Page 21 Test Methods Test 8 Calcium Hardness Test 10 Iron/1 Range: 0-500mg/l (ppm) CaCO Range: 0-1.00mg/l (ppm) Fe Colour change: Violet - Orange Colour change: Colourless - Pink 1 Fill test cuvette with sample to the 10ml mark. 1 Fill test cuvette with sample to the 10ml mark. 2 Add one Calcicol No 1 tablet, 2 Add one Iron LR tablet, crush and mix to dissolve.
  • Page 22 Test Methods Test 77 Water Balance Note: the Palintest Water Balance test has been calculated for an average heated swimming pool (82°F, To determine Water Balance Index, select either 28°C). For unheated swimming pools, subtract 0.1 Palintest or Langelier from the System Mode from the index value obtained.
  • Page 23: Calibration/Validation

    Calibration/Validation 8.0 Calibration/Validation Your Pooltest 9 Bluetooth is delivered with a 8.2 Enter Check Standard Values calibration certificate validating the performance Each standard has two values assigned, for two of the instrument as it leaves Palintest. individual wavelengths. We recommend annual service and calibration of all photometric instruments in normal use.
  • Page 24: Photometric Testing Hints And Tips

    Remember to dilute the sample to the 10 Ensure your Pooltest 9 Bluetooth is operating same extent for analysis. effectively by using Palintest Check Standards and the Check Standard Mode (see Section...
  • Page 25: Troubleshooting

    Photometers may fail the Check Standard validation and battery life. The Info panel indicates the status step due to the requirement for service/calibration. of the Pooltest 9 Bluetooth and any specific fault Contact your local Palintest partner for service conditions are defined and displayed on screen.
  • Page 26 Battery/Power Issues The Pooltest 9 Bluetooth communicates seamlessly My batteries are running out too quickly with the Palintest Aqua Pal app. In the event of Use good quality batteries and always replace the any errors the Pooltest 9 Bluetooth will display batteries completely when indicated on the Info Panel.
  • Page 27 Care and Maintenance the gasket is correctly located to prevent any water ingress. Tighten the screws carefully The Pooltest 9 Bluetooth contains no user- but do not overtighten. serviceable parts internally. User maintenance is only recommended for cleaning of the optical chamber, changing batteries and validating performance using the Check Standard Mode.
  • Page 28: Technical Specifications

    To computer via USB using Hard Disk or COM port mode. Wireless Bluetooth SMART download, either instantly or as a data batch, using a connected device running the Palintest Aqua Pal app. Optional Palintest Portal data management available Data Output Format...
  • Page 29: Spares And Consumables

    EDTA Tablets, 250 pack AT 090 DPD Oxystop, 250 pack AP 017 Check Standards/Service for Pooltest 9 Bluetooth PT 791 Pooltest 9 Bluetooth Check Standards Validation standards for Pooltest 9 Bluetooth ® with certificate. Supplied in hard transport/storage case 06233...
  • Page 30: Palintest Aqua Pal App And The Palintest Portal

    Appendix 5 - Palintest Aqua Pal App and the Palintest Portal What is the Aqua Pal App? Connecting to the Aqua Pal App Generating reliable and accurate water test data Enable Bluetooth on the Pooltest 9 Bluetooth. is only part of the process of managing swimming The icon will appear on the Info Panel showing pools, spas, hydrotherapy pools and hot tubs.
  • Page 31 Appendix 5 - Palintest Aqua Pal App and the Palintest Portal Connecting with the Palintest Portal Also included with the Aqua Pal app is the secure Palintest Portal found at https://palintestportal.com Data stored in the Aqua Pal app can be uploaded to the Palintest Portal when an internet connection is available.
  • Page 32 Palintest Ltd Palintest House, Kingsway, Team Valley, Gateshead, NE11 0NS Tel: +44 (0)191 491 0808 Fax: +44 (0)191 482 5372 sales@palintest.com (UK) export@palintest.com (International) Palintest Australia and Asia Pacific 1/53 Lorraine Street, Peakhurst Business Centre, Peakhurst, NSW 2210, Australia Tel: +61 1300 131516 Fax: +61 1300 131986 palintest@palintest.com.au...

Table of Contents