  • Page 1 Translation of the original Operating manual RS 500 Version 05/2012 Paint resistance meter...
  • Page 3: Table Of Contents

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL Contents ABOUT THESE INSTRUCTIONS Languages Warnings, notes and symbols in these instructions GENERAL SAFETY INSTRUCTIONS Safety instructions for the operator 2.1.1 Electrical equipment 2.1.2 Personnel qualifi cations 2.1.3 Safe work environment Safety instructions for staff 2.2.1...
  • Page 4: About These Instructions

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL ABOUT THESE INSTRUCTIONS This operating manual contains information about the operation, repair and maintenance of the unit. Always observe these instructions when operating the device. This equipment can be dangerous if it is not operated in accordance with this operating manual.
  • Page 5: General Safety Instructions

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL GENERAL SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS FOR THE OPERATOR Keep these operating instructions to hand near the unit at all times. Always follow local regulations concerning occupational safety and accident prevention. 2.1.1...
  • Page 6: Safety Instructions For Staff

    Wear suitable protective clothing when working with hot materials. CORRECT USE WAGNER accepts no liability for any damage arising from incorrect use. Only use the unit to work with the materials recommended by WAGNER. Only operate the entire unit. Do not deactivate safety fi xtures.
  • Page 7: Guarantee And Conformity Declarations

    The manufacturer will not be held liable or will only be partially held liable if third-party accessories or spare parts have been used. With genuine WAGNER accessories and spare parts, you have the guarantee that all safety regulations are complied with.
  • Page 8: Ce Declaration Of Conformity

    - DIN EN 61000-6-4: 2011 Marking: EC certifi cate of conformity The certifi cate is enclosed with this product. The certifi cate of conformity can be reordered from your WAGNER representative, quoting the product and serial number. Order number: 2326376...
  • Page 9: Description

    OPERATING MANUAL DESCRIPTION FIELDS OF APPLICATION, USE IN ACCORDANCE WITH THE INSTRUCTIONS The paint resistance meter RS 500 is used to measure the paint resistance of solvent-based paints. The meter is not suitable for measuring the resistance of water-based paints!
  • Page 10: Technical Data

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL TECHNICAL DATA Supply voltage 18 V DC (two 9V batteries) Measuring range 10 kΩ - 5 MΩ Cell constant K Weight (including probe) 1360 g; 3.00 lb Operating temperature range 5 °C - 40 °C; 41 °F - 104 °F...
  • Page 11: Conversion Of The Resistance Of Paint

    OPERATING MANUAL CONVERSION OF THE RESISTANCE OF PAINT The meter RS 500 measures the paint resistance in ohms (Ω), kiloohms (kΩ) or megaohms (MΩ). To convert this measured paint resistance from kΩ into the specifi c resistance value in kΩ.cm, the measurement can be multiplied by the cell constant.
  • Page 12: Operating Elements And Connections

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL OPERATING ELEMENTS AND CONNECTIONS Display scale Meter Measuring probe Rotary switch for functions Potentiometer for zero calibrate Measuring probe connection...
  • Page 13: Display Scale

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL DISPLAY SCALE Display showing resistance value fi gures Display showing resistance value ranges Battery test Needle position for zero calibrate Resistance range Suitability of coating material < 50 kΩ Resistance value too low 50 kΩ...
  • Page 14: Start-Up And Operation

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL START-UP AND OPERATION Observe safety instructions in chapter 2. STARTING UP METER Procedure: Position unit horizontally. Insert measuring probe at connection (arrow).
  • Page 15: Undertaking Zero Calibration

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL UNDERTAKING ZERO CALIBRATION Note: A zero calibration must always be undertaken before probing! Procedure: Turn right "Functions" rotary switch to "ZERO CALIBRATE". Turn potentiometer for zero calibrate until the scale indicator is at the "Adjust"...
  • Page 16: Undertaking Battery Test

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL UNDERTAKING BATTERY TEST Note: A zero calibration must always be undertaken before the battery test! Procedure: Turn right "Functions" rotary switch to "BATTERY TEST". The battery status is indicated on the scale (see chap. 4.6).
  • Page 17: Measuring Resistance Of Paint

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL MEASURING RESISTANCE OF PAINT DANGER Use in area at risk of explosion! Explosion hazard. Position container for probing outside area at risk of explosion! Earth container! Note: Zero calibration and a battery test must always be undertaken before probing! The probe must be cleaned before each measurement.
  • Page 18 RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL Probing: Turn right "Functions" rotary switch to "RESISTIVITY TEST". Always immerse measuring probe in liquid down to mark (see arrow in diagram on left). Note: The measuring probe must not touch the container during probing! Read value off the scale and compare with value in table below.
  • Page 19: Cleaning The Probe

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL CLEANING THE PROBE WARNING Improper cleaning! Risk of injury and damage to the equipment. De-energize the unit electrically. Ensure that the cleaning agent's fl ash point is at least 15 K above the ambient temperature or that cleaning is undertaken on a station with guaranteed ventilation.
  • Page 20: Trouble Shooting And Solution

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL TROUBLE SHOOTING AND SOLUTION Functional fault Cause Remedy Zero calibration not possible Battery fl at Replace battery Meter defective Wagner Service Battery test not good Zero calibration not Undertake zero calibration...
  • Page 21: Maintenance And Repair

    RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL MAINTENANCE AND REPAIR CLEANING THE UNIT The probe must be clean if the paint resistance is to be measured accurately. The probe must therefore always be cleaned thoroughly before and after probing! A suitable solvent must be used to clean the probe.
  • Page 22 RS 500 VERSION 05/2012 ORDER NUMBER DOC2330092 OPERATING MANUAL Cut open cable ties on the two batteries with wire cutters and remove. Push batteries gently towards the housing wall and remove from above. Swivel new batteries (9V block battery) into holder and insert (note terminal connections, see diagram below).
  • Page 23: Product Disposal

    Wagner or one of our dealers will take back your used Wagner electrical or electronic equipment and will dispose of it for you in an environmentally-friendly way.
  • Page 24 RS 500 VERSION 03/2012 ORDER NUMBER DOC2326375 OPERATING MANUAL...
  • Page 25 RS 500 VERSION 03/2012 ORDER NUMBER DOC2326375 OPERATING MANUAL...
  • Page 26 DK- 8600 Silkeborg Telephone: +32 (0)2 269 4675 Telephone: +45 70 200 245 Telefax: +32 (0)2 269 7845 Telefax: +45 86 856 027 E-Mail: info@wsb-wagner.be / HP www.wsb-wagner.eu E-Mail info@wagner-industri.com United Kingdom France WAGNER Spraytech (UK) Ltd. J. WAGNER France S.A.R.L.
  • Page 28 Order no. 2330092 Germany J. WAGNER GmbH Otto-Lilienthal-Str. 18 Postfach 1120 D- 88677 Markdorf Telephone ++49/ (0)7544 / 5050 Fax ++49/ (0)7544 / 505200 E-mail: service.standard@wagner-group.com Switzerland J. WAGNER AG Industriestrasse 22 Postfach 663 CH- 9450 Altstätten Telephone ++41/ (0)71 / 757 2211 Fax ++41/ (0)71 / 757 2222 E-mail: rep-ch@wagner-group.ch...

Table of Contents