Electrical Data [X1], [X3] - Festo CMMS-AS G2-STO Series Manual

Motor controller
Table of Contents

Advertisement

A
Technical appendix
A.1.3

Electrical data [X1], [X3]

Control ports DIN4, DIN5 [X1.21, X1.9]
Nominal voltage
Voltage range
Nominal current
Input voltage threshold
Switching on
Switching off
Switching time from high to low [ms]
Switching time from low to high [ms]
Maximum test impulse length
Tab. A.5
Technical data: Electrical data for the inputs at [X1]
Control port Rel [X3.2]
Nominal voltage
Voltage range
Nominal current
Input voltage threshold
Switching on
Switching off
Switching time from high to low [ms]
Switching time from low to high [ms]
Maximum test impulse length
Service life of relay input, switching cycles n
CMMS-AS-...-G2 Rev. 01
CMMS-AS-...-G2 Rev. 02
Tab. A.6
Technical data: electrical data of the control port Rel [X3]
Acknowledgment contact NC1, NC2 [X3.5, X3.6]
Feature
Max. voltage
Nominal current
Switching time closing
Switching time opening
Service life of acknowledgment contact, switching cycles n
the service life is reduced with higher load currents)
CMMS-AS-...-G2 Rev. 01
CMMS-AS-...-G2 Rev. 02
Tab. A.6
1) Switching time
Tab. A.7
Technical data: electrical data of the acknowledgment contact NC1/NC2 [X3]
38
[V]
24 (related to 0 V)
[V]
19.2 ... 28.8
[mA]
2.5 (typical; maximum 3)
[V]
13.1
[V]
3.4
5
8
[µs]
Not specified; no tolerance against test impulses
[V]
24 (related to 0V)
[V]
19.2 ... 28.8
[mA]
20 (typical; maximum 30)
[V]
17.9
[V]
2.5
12
20
[µs]
Not specified; no tolerance against test impulses
op
[n
]
100 000
op
6
[n
]
10 x 10
op
Relay contact, normally closed
[V DC]
30
[mA]
2000 at 30 V
[ms]
(Switching time from high to low
[ms]
(Switching time from low to high
[n
]
100 000
op
6
[n
]
10 x 10
op