Xpelair Simply Silent Contour C4S Installation And Maintenance Instructions Manual

Xpelair Simply Silent Contour C4S Installation And Maintenance Instructions Manual

Advertisement

Xpelair Simply Silent
Installation and Maintenance Instructions
C4S (92960AW)
C4R (92961AW)
C4TS (92962AW)
C4TR (92963AW)
Contour
C4PS (92964AW)
C4PR (92965AW)
C4HTS (92966AW)
C4HTR (92967AW)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Simply Silent Contour C4S and is the answer not in the manual?

Questions and answers

Summary of Contents for Xpelair Simply Silent Contour C4S

  • Page 1 Xpelair Simply Silent ™ Contour Installation and Maintenance Instructions C4S (92960AW) C4TS (92962AW) C4PS (92964AW) C4HTS (92966AW) C4R (92961AW) C4TR (92963AW) C4PR (92965AW) C4HTR (92967AW)
  • Page 2: Installation And Maintenance Instructions

    Installation and Maintenance Instructions Standard Timer Pull Cord Humidistat, Timer C4S (92960AW) C4TS (92962AW) C4PS (92964AW) C4HTS (92966AW) C4R (92961AW) C4TR (92963AW) C4PR (92965AW) C4HTR (92967AW) • Do read the entire instruction leaflet before commencing installation. • Do install each fan with a means for disconnection in all poles in the fixed wiring. • Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning. • Please leave this leaflet with the fan for the benefit of the user.
  • Page 3: Overall Dimensions (Mm)

    This appliance is intended for All Xpelair Simply Silent™ Contour connection to fixed wiring. Check AC fans have the following features: that the electrical rating shown on • Two speed extraction each fan matches the mains supply. (Selectable at installation) THE APPLIANCE IS DOUBLE INSULATED • Built-in back draught shutter AND DOES NOT REQUIRE AN EARTH C4S/C4R - Operate the fan using an on/off CONNECTION. switch (not supplied). All installations must be supervised by a qualified electrician. Installations and wiring C4PS/C4PR - Operate the fan using an integral must conform to current IEE Regulations pull-cord. (UK), local or appropriate regulations (other C4TS/C4TR* - Built-in timer operates fan for a countries). preset delay from 30 seconds to 30 minutes.
  • Page 4: Front Cover Removal

    Back plate Wall tube fixing positions quick fit clamps QUICK FIT CLAMP Front cover removal IMPORTANT – PLEASE READ Adjusting the humidity setting Fan switches on Fan does not at lower level of switch on until condensation higher level of (anti-clockwise) condensation (clockwise) MORE SENTITIVE (RH = 50%) LESS SENTITIVE (RH = 95%) Factory settings: Timer 15 minutes, RH 75% Adjusting the run on timer setting Fan runs on for a Fan runs on for a shorter time when...
  • Page 5: Wiring And Setting Up

    Wiring and Setting Up SEE DETAIL A DETAIL A SCALE 2.000 HIGH LOW SPEED SPEED SET JUMPER TO REQUIRED POSITION CUSTOMER FOR SPEED SETTING CONNECTION TERMINAL C4S / C4R C4PS / C4PR LEVEL LINE DETAIL B SCALE 2.000 SEE DETAIL B HIGH SPEED LOW SPEED CUSTOMER CONNECTION TERMINAL SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING C4TS / C4TR LEVEL LINE...
  • Page 6: Installation

    Wet Rooms: On/Off switch must • A 100mm diameter prepared hole. be situated so that it cannot be • Appropriate ancillaries for termination. These touched by persons making use of items are available from Xpelair: the bath or shower. 1. 3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use For Australia Only – C4S /C4R / C4PS / insulated duct ref: 89847AA.
  • Page 7: Fan Settings

    C6S/C6R C6PS/C6PR TERMINALS FUSE DOUBLE POLE ISOLATING SWITCH For fixed wiring circuits the protective fuse for the appliance must not exceed 5A. C4TS/C4TR ON/OFF C4HTS/C4HTR TERMINALS SWITCH LAMP (IF REQUIRED) FUSE DOUBLE POLE ISOLATING SWITCH Preparing the Fan for installation. 8. Insert the fan tube of the back-plate into 1. Remove the front cover/baffle assembly by the wall duct/ceiling as before. depressing the latch on the underside of 9.
  • Page 8: Using The Fan

    Please recycle where facilities exist. C4HTS /C4HTR Only. Check with your local authority for • Automatic mode - The fan automatically recycling advice. adjusts to slow changes in natural humidity levels without operating the fan. If the humidity levels increase at a rate slower Guarantee than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered UK only by humidity. This is to prevent nuisance We, Redring Xpelair Group Limited, provide a triggering of the fan. If humidity levels guarantee against faulty parts and manufacture increase quicker than 5% RH in 5 minutes for a period of 2 years from the date of the fan will operate. When relative humidity purchase. In the unlikely event of a product drops the fan continues to operate for the breakdown during the guarantee period the adjustable time delay. product should be returned to the place of • External operation - Use the external on/off purchase or to Redring Xpelair Group Limited. switch. When the fan is switched off, the fan continues to operate for the adjustable time Exclusions delay then goes into automatic mode.
  • Page 9 Technical advice and service Customers outside UK - see international below. United Kingdom Xpelair have a comprehensive range of services including: • Free technical advice help-desk from Engineers on all aspects of ventilation. • Free design service, quotations and site surveys. • Service and maintenance contracts to suit all requirements. Please ask for details: • By telephone on Techline: +44 (0) 844 372 7766 • By fax on Techfax: +44 (0) 844 372 7767 • At the address below Head Office, UK Sales Office and Spares Redring Xpelair Group Ltd,...
  • Page 10 Head Office, UK Sales Office and Spares Redring Xpelair Group Ltd, Newcombe House, Newcombe Way, Orton Southgate, Peterborough, PE2 6SE England Telephone: +44 (0) 844 372 7761 www.xpelair.co.uk www.xpelair.co.uk/international FM02118 ISO 9001: 2000 Part No: 25332AA (Revision D)

Table of Contents