King Edge Vac
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
ISSUE
(continued from previous page)
Unit Does Not Start
No Message Displayed
Unit Does Not Start
Standard Display, No Error Mes-
sage
Unit Does Not Start
Message reads:
CENTER STOP INTERLOCK/
!SERVICE OR CLEAR FAULT!
LEFT SIDE STOP/INTERLOCK/
!SERVICE OR CLEAR FAULT!
RIGHT SIDE STOP/
INTERLOCK/!SERVICE OR
CLEAR FAULT!
Unit Does Not Start
Message reads:
CIRCUIT BREAKER TRIPPED!
SERVICE OR CLEAR FAULT
INVERTER/MOTOR OVER-
LOAD!
SERVICE OR CLEAR FAULT
(continued on next page)
Troubleshooting
POSSIBLE CAUSE
13. No voltage is available
to the DC power supply
card.
14. DC power supply is
faulty.
1. PX6 is on or has failed.
1. A safety switch is open in
the starting circuit.
1. A circuit breaker or motor
protector have tripped.
2. Check the motor thermo-
stat connections, and the
temperature of the motor.
If the connections are
correct, and the motor sur-
face is extremely hot, the
internal motor thermostat
is tripped.
TOC
INDEX
Troubleshooting
WARNING
Read the REPAIR chapter and make
sure that the power is disconnected
before doing any repairs.
SOLUTION
•
Press and hold the START button. If
there is no indicator light on the power
supply card, check and replace circuit
breaker (CB0 or CB1), start switch
contacts or wiring, as necessary.
•
Press and hold the START button. If
no 5VDC indicator on main control
board check and replace power supply
card or wiring to main control card, as
necessary.
•
Check. Adjust/replace as necessary.
Refer to the REPAIR chapter, Sensors
section and the appropriate procedure.
•
Locate and close any open interlock
switch.
•
Locate the tripped circuit breaker or
the tripped motor protector in its elec-
trical panel and reset it. If the breaker
continues to trip, determine and cor-
rect the cause.
•
When the motor has cooled, the ther-
mostat will automatically reset. Check
the motor load. Call the factory Service
Department if the motor thermostat
trips repeatedly.
6-11
Need help?
Do you have a question about the King Edge VAc and is the answer not in the manual?
Questions and answers