Pentair ChemCheck Installation And Service Manual
Pentair ChemCheck Installation And Service Manual

Pentair ChemCheck Installation And Service Manual

Water quality monitor

Advertisement

CHEMCHECK™
WATER QUALITY MONITOR
Digital copies of all ChemCheck
manuals, as well as translated versions,
can be found at www.pentair.com, or by
scanning the provided QR code.
• Install and Service Guide (P/N 523397)
• Quick Start Guide (P/N 523510)
• User's Guide (P/N 523513)
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Se pueden encontrar copias digitales de
todos los manuales de ChemCheck, así como
versiones traducidas en www.pentair.com, o
escaneando el código QR proporcionado.
• Guía de instalación y servicio (P/N 523509)
• Guía de inicio pápido (P/N 523512)
• Guía del usuario (P/N 523515)
INSTALL AND
SERVICE GUIDE
Des copies numériques de tous les manuels
ChemCheck, ainsi que les versions traduites,
peuvent être trouvées sur www.pentair.com,
ou en scannant le code QR fourni.
• Guide d'installation et d'entretien (P/N 523508)
• Guide de démarrage rapide (P/N 523511)
• Guide d'utilisation (P/N 523514)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ChemCheck and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair ChemCheck

  • Page 1 Se pueden encontrar copias digitales de Des copies numériques de tous les manuels manuals, as well as translated versions, todos los manuales de ChemCheck, así como ChemCheck, ainsi que les versions traduites, can be found at www.pentair.com, or by versiones traducidas en www.pentair.com, o peuvent être trouvées sur www.pentair.com,...
  • Page 2: Important Safety Instructions

    This guide provides installation and operation instructions for this product. Consult Pentair with any questions regarding this equipment. the installation and use of this product. Consult your local building and health codes for more information.
  • Page 3 : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. CHEMCHECK™ Water Quality Monitor Install and Service Guide...
  • Page 4: Table Of Contents

    CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Pentair replacement parts, and pool products, please contact: Customer Service and Technical Support, USA Sanford, North Carolina (8 A.M. to 4:30 P.M. ET) (8 A.M. to 4:30 P.M. — Eastern/Pacific Times)
  • Page 5: Introduction

    Oxidation-Reduction Potential (ORP) and 3. Installation Kit temperature. When paired with the Pentair Home app, the ChemCheck allows for easy and real-time remote • Screw Anchors (Qty. 4) monitoring of pool water chemistry and temperature. • Mounting Screws (Qty. 4) •...
  • Page 6: Installation

    5. Install a provided mounting screw into each predrilled hole. Figure 1 6. Use the Inner Mounting Points (2) to seat ChemCheck onto the screws. 7. If the mounting surface allows, ChemCheck should be secured to the wall at the Outer Mounting Points (3).
  • Page 7: Plumbing Chemcheck

    A licensed plumber should perform all plumbing installation, as they will be familiar with all local, state and national codes. Pentair recommends plumbing ChemCheck in one of two ways, dependent on whether a heater is part of the filtration loop.
  • Page 8 13. Push the tubing onto the barbed end of fitting and hand tighten the Fitting Nut (5). See D Figure 3. Figure 3 14. Route free end of the tubing to ChemCheck. 15. Loosen the white compression nut on IN side of ChemCheck.
  • Page 9: Electrical Installation

    ChemCheck. 5. Reinstall the top cover onto ChemCheck. 6. If all other installation procedures have been completed, immediately continue to Initial Startup, page 6. Figure 5 CHEMCHECK™ Water Quality Monitor Install and Service Guide...
  • Page 10: Operation

    ChemCheck is receiving insufficient water flow. Recalibration is recommended in the following cases: 7. If the Flow Indicator is not visible, then ChemCheck is ready to be calibrated. • At the beginning of each pool season. Refer to the ChemCheck Quick Start Guide or •...
  • Page 11: Maintenance

    MAINTENANCE Manually Testing Water Quality Battery Usage and Storage Requirements Every two weeks the Pentair Home app paired to your ChemCheck™ Water Quality Monitor will request a retest Read all safety warnings and instructions. Failure of your water chemistry. to follow the warnings and instructions below may Refer to Balancing your Pool, page 2 for instructions on result in electric shock, fire and/or serious injury.
  • Page 12: General Electrode Care

    Figure 9 OFF at the circuit breaker. This will prevent unexpected start-ups during servicing. 2. Ensure both ChemCheck flow valves are closed. 3. Remove the top cover from ChemCheck. 4. Disconnect the Electrode Connector (1). 5. Carefully unscrew Electrode (2) counter-clockwise and gently remove it from cell reservoir.
  • Page 13: Winterizing

    1. Ensure all power to the filtration pump is turned OFF at the circuit breaker. This will prevent unexpected start-ups during servicing. 2. Ensure both ChemCheck flow valves are closed. See Figure 10. 3. Remove the top cover from ChemCheck.
  • Page 14: Troubleshooting

    (Solid Blue, Solid Green, and Solid Purple LEDs) readings will restart after this pause. Start a status check sequence by pressing the Status Button once. The Status LED will illuminate and ChemCheck will cycle through the three separate status checks. The chart below shows the order in which statuses will display and...
  • Page 15: Replacement Parts

    523526 Tube Fitting 606000100z Battery Pack 523387z Antenna 523385z Battery Cover 523396z Base Assembly 523541 (includes Items 2, 3 and 14) Electrode 523399z Drain Plug Assembly 523522 Reservoir 523506z Reservoir O-ring 523516z CHEMCHECK™ Water Quality Monitor Install and Service Guide...
  • Page 16 WWW.PENTAIR.COM All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.

Table of Contents