Co2 storage refrigerator and freezer cabinets, ic (integrated controller), danfoss controller (akcc550a) or carel controller (mpxpro), nc (no controller) controller chosen and fitted by external technician
Table of Contents

Advertisement

Appendix I
Gram factory settings for AKCC550A (U/KG/FG cabinets)
Min. OFF-time
Time delay for cut in of comp.2
Defrost
Defrost method: 0=Off, 1= EL, 2= Gas
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cut in of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cutin during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
Defrost sensor: 0 =Stop on time, 1=S5, 2=S4, 3=Sx
(Application 1-8 and 10: both S5 and S6.
Application 9: S5 and S5B)
Pump down delay
Drain delay (used at hot gas defrost only)
Max. aggregate refrigeration time between two defrosts
Heat in drip tray. Time from defrosting stops to heating in
the drip tray is switched off
Adaptive defrost:
0=not active, 1=monitoring only, 2=skip allowed day, 3=skip
allowed both day and night, 4=own assessment
+ all schedules
Time delay before opening of hot gas valve
Rail heat during defrost 0=off. 1=on. 2=Pulsating
Max. duration of -d- in display
c02
0
c05
N/A
d01
EL
d02
6
d03
6
d04
30
d05
0
d06
4
d07
0
d08
-1
d09
0
d10
1
d16
0
d17
N/A
d18
0
d20
N/A
d21
0
d23
N/A
d27
0
d40
30
0
0
N/A
N/A
EL
EL
6
6
6
6
30
30
0
0
4
4
0
0
-1
-1
0
0
1
1
0
0
N/A
N/A
0
0
N/A
N/A
0
0
N/A
N/A
0
0
30
30