Adding Refrigerant - Bosch Climate 5000 Series Installation Manual

Wall mounted ductless single split air conditioner / heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Installation Manual

8.3 Adding Refrigerant

In North America, the standard pipe length is 7.5m (25'). The additional refrigerant
to be charged can be calculated using the following formula:
Additional refrigerant per pipe length
Connective Pipe
< Standard pipe length
> Standard pipe length
Table 8
CAUTION: CONTAINS REFRIGERANT
 NEVER mix refrigerant types.
Bosch Thermotechnology Corp. | 03.2019
Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 25
Air Purging
Vacuum Pump
Liquid Side: Ø 6.35 (ø 0.25")
Vacuum Pump
(Pipe length – standard length) x 15g/m
(Pipe length – standard length) x 0.16oZ/ft
Additional Refrigerant
N/A
Inverter R410A:
Liquid Side: Ø 9.52 (ø 0.375")
Inverter R410A:
(Pipe length – standard length) x 30g/m
(Pipe length – standard length) x 0.32oZ/ft
Data subject to change