Troubleshooting Tips
Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions below to see if
the problems can be resolved before having to contact the service department.
Problem
The portable air conditioner
does not turn on
The unit turns on but the com-
pressor does not turn on (the fan
runs but the unit is not cooling)
The air coming out of the unit is
not very cold, or the airflow
volume is weak
Page 22
Possible Causes
Power failure / outage
The automatic switch, line fuse, or
breaker has been tripped
The power supply voltage is too low
The power cord is damaged
The L.C.D.I. power plug for the unit is
tripped
The internal water reservoir is full and
'P1" appears on display
The room temperature is outside of the
operational tolerances of the unit
The Cooling mode is not on
The compressor has not turned on yet
because of its time delay
The set temperature is too high
The internal water reservoir is full and
'P1" appears on display
The filters are dirty or obstructed
The air intake or exhaust is ob-structed
The unit is set in DRY or FAN mode
The unit is set to low fan speed
Solutions
Restore the power supply
Flip the switch / change the fuse / turn the
breaker back on. Also note that you may
have too many appliances drawing power on
one circuit, you may need to move the other
appliances to another circuit
Move the unit onto another circuit with the
correct voltage
Call for service. Only authorized personnel
should replace damaged power cord or
power plug
Press the Reset button on the L.C.D.I. power
plug
Drain water from the air conditioner
Possible loose internal connection. Please
contact Whynter for service
This unit is designed to work in ambient
temperatures of 63°F to 90°F
Press the MODE button until the COOL light
is shown on the display
Give the compressor 3 minutes to turn on
after the Cooling mode has been selected
Set the air conditioner to a lower tem-
perature. It is recommended to set the
temperature to at least 5°F of the ambient
temperature
Either manually drain the water by removing
the drain plug or allow the unit to exhaust
the water itself by run-ning the fan only
mode. Then cooling will resume
Possible loose internal connection. Please
contact Whynter for service
Clean the air filters
Make sure there is at least 20" of
clearance from the air intake. Make the
length of the exhaust hose is as short as
possible
Set the unit to the cooling mode
Set the unit to a higher fan speed