Whirlpool LDR3822P Dimensions

Whirlpool LDR3822P Dimensions

120-volt electric compact dryer

Advertisement

Quick Links

®
120-Volt Electric Compact Dryer
PRODUCT MODEL NUMBERS
LDR3822P
Electrical: 120-volt, 60-Hz, AC-only, 15- or
20-amp. electrical supply. A time-delay fuse or
circuit breaker is recommended. Use a separate
electrical circuit.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.
RECESSED AREA AND CLOSET INSTALLATION
Recessed or closet installation - Dryer only
A
A. Side view - closet or confined area
B. Recessed area
EXHAUST VENTING
Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
Louvered style
Number of
Type of
90° turns
vent
or elbows
0
Rigid metal
Flexible metal
1
Rigid metal
Flexible metal
2
Rigid metal
Flexible metal
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
OVERALL DIMENSIONS
*Most installations require a
minimum 5-1/2 in. (14.0 cm)
clearancebehind the dryer for the
exhaust vent with elbows.
Closet confined area
For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.
B
4"
(10.2 cm)
2.5"
(6.4 cm)
Angled style
Box or
Angled
louvered
hoods
hoods
36 ft (11 m)
26 ft (7.9 m)
28 ft (8.5 m)
22 ft (6.7 m)
26 ft (7.9 m)
16 ft (4.9 m)
18 ft (5.5 m)
12 ft (3.7 m)
16 ft (4.9 m)
6 ft (1.8 m)
8 ft (2.8 m)
2 ft (0.6 m)
†Height with caster is 32¹⁄₂" (82.6 cm)
Recessed or closet installation - Stacked
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
1. Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns. When using
elbows or making turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90° turns when possible.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum
vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible
metal), find the maximum length of metal vent on the same line as the number of
elbows.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.