Introduction
WARNING: Read and understand the safety
chapter before you assemble the product.
To select the correct hoses for the

operation

Use hoses and hose connectors with a supplied
hose clamp.
Make sure that the hoses cannot compress during
operation. The hoses must have a strong
construction.
Make sure that the hoses are fully sealed and that
there are no types of holes in the hoses.
Make sure that the suction hose aligns with the
dimension of the suction inlet. For information about
minimum hose dimension, refer to
page 13 .
Make sure that the suction hose is not too long for
the operation to keep the best result. Obey the
Introduction
WARNING: Read and understand the safety
chapter before you install the product.
To install the product
1. Put the product on stable and level ground near the
water surface.
2. Make sure that the product has a free space of a
minimum of 1 m.
3. Make sure that there are no flammable objects near
the engine.
Introduction
WARNING: Read and understand the safety
chapter before you use the product.
To do before you operate the product
Make sure that the product is on level ground.
Make sure that the ON/OFF switch is in the OFF
position.
8

Assembly

To install the suction hose to the
product
1. Attach the hose connector (A) to the suction hose
2. Install the strainer (D) at the end of the suction hose
3. Tighten the hose connector on the pump suction
To install the discharge hose
1. Attach the hose connector (A) to the pump outlet.
Technical data on
2. Install the discharge hose (B) to the hose connector

Installation

4. Make sure that the level difference for the suction
5. If the discharge hose (D) must be installed across a
Operation
instructions for installation of the product. Refer to
Installation on page 8 .
Select a short discharge hose with a large diameter
to get the best result.
(B) with a hose clamp (C). Make sure that the
sealing washer for the hose connector is in good
condition. (Fig. 14)
with the hose clamp (E).
inlet (F).
(Fig. 15)
and tighten the hose clamp (C).
hose (A) is as low as possible for the operation. The
level difference for the suction hose must not be
more than 7.5 m/25 ft. (Fig. 16)
Note: The level difference for the discharge hose (B)
can be more if it is necessary. But, a lower total level
difference (C) gives the best result.
road, put it perpendicular to the flow of the traffic. Put
long wooden blocks (E) on the 2 sides of the
discharge hose for protection. (Fig. 17)
Examine the product for damages. Make sure that
there are no fuel or oil leaks.
Remove unwanted material from the product. Clean
carefully around the muffler and the starter unit.
Make sure that all nuts, bolts, screws and hose
connectors and clamps are tight.
Make sure that there is no damage on the suction
hose or discharge hose.
Make sure that the sealing washer and strainer on
the suction hose connector is installed correctly and
not damaged.