Introduction Document Scope This document describes the installation, configuration and operation of the ECP-AA1 Intercom. Products Item Number Item Name 1008192011 ECP-AA1 Intercom Publication Log Revision Date Author Status 18.5.2016 HVD/HKL Published 16.9.2019 New doc no. A100K11789 Related Documentation Doc. no. Documentation A100K11194 Turbine IP Intercoms Technical Manual...
Installation & Mounting The ECP-AA1 is flush-mounted using 4 screws of type: • M4x16 DIN 7991 A4 – Flat Head Socket Cap Screw, Stainless Steel A4 DIN7991 • Length as required ECP-AA1 Installation, Configuration & Operation A100K11789...
Connectors & Power Connectors The ECP-AA1 has 2 connectors located at the bottom of the unit. 3.1.1 Ethernet Connector Type: M12, D-coded, Female, 4-pin 3.1.2 I/O Connector Type: M12, A-coded, Female, 8-pin +5V DC I/O 1 I/O 2 I/O 3 Relay –...
Connection to Emergency Break The emergency break provides a clean contact to the ECP-AA1. Its purpose is so that an emergency call is made as soon as the emergency break handle is operated. Procedure • Connect the clean contact between pins 2 and 3 on the I/O connector. Connection to CCTV System The ECP-AA1 provides a clean contact to the CCTV system.
Configuration Initial Setup The ECP-AA1 is delivered with factory default settings. By default, the unit’s IP settings are configured according to DHCP. To configure the unit: 1. Press the call button on the unit for it to speak its IP address 2.
Audio Settings Normally no changes are required to be made to the audio settings, but depending on the specific circumstances where the unit is installed, minor adjustments may be needed. • Select SIP Configuration > Audio Settings On this page it is possible to set: •...
I/O Settings • Select SIP Configuration > I/O Settings Under Configuration set the following values for the I/O Pins: I/O Pin 1: Input 1 I/O Pin 2: Input 2 or Output 2 – depending on the application for which this I/O will be used I/O Pin 3: Input 3 or Output 3 –...
Output Settings • Select SIP Configuration > Relay Settings 4.4.1 CCTV Interface For Choose Relay To Configure: • Select Relay 1 Under Configuration set the following values: Outgoing Ringing: On Idle: Off • Click Save ECP-AA1 Installation, Configuration & Operation A100K11789...
4.4.2 General Settings For Choose Relay To Configure: • Select Output 5 Under Configuration set the following values: Outgoing Ringing: Slow flash Outgoing Call: Off Idle: Off • Click Save ECP-AA1 Installation, Configuration & Operation A100K11789...
Page 12
For Choose Relay To Configure: • Select Output 6 Under Configuration set the following values: Outgoing Call: On Idle: Off • Click Save ECP-AA1 Installation, Configuration & Operation A100K11789...
Call Button Settings Both the call button on the unit and the emergency break input are set up as a call button. • Select SIP Configuration > Direct Access Key Settings Assuming that the call button should call a fixed number: •...
4.5.1 Ringlist Settings Optionally it is possible to make the ECP-AA1 call numbers in sequence until the call is accepted. If this is the requirement, make the settings as shown below: • Under the parameter Option select Ringlist 1 for both Input 1 and Input 4 •...
SIP Configuration For the ECP-AA1 to be able to register to a SIP server, the correct SIP settings must first be done. • Select SIP Configuration > SIP Settings • Enter values for : Display Name, Directory Number (SIP ID), Server Domain (SIP), Authentication User Name •...
Operation The ECP-AA1 Intercom is a user-friendly Emergency Call Point with a single call button. Speaker Indication LED Call Button Microphone To make a call: • Press the call button o The red illumination ring around the call button will start flashing o A ring-back tone will be audible from the speaker When the operator accepts the call: o The green LED will be lit, indicating that 2-way communication is now possible...
Page 17
August 2005, and should be disposed of separately from normal household waste so that they can be recycled. DOC NO. customer.service@zenitel.com A100K11789 ZENITEL PROPRIETARY. This document and its supplementing elements, contain Zenitel or third party information which is proprietary and confidential. Any disclosure, copying, distribution or...