USER MANUAL AND SPECIFICATIONS NI cRIO-9025 Intelligent Real-Time Embedded Controller for CompactRIO This document describes how to set up and use the NI cRIO-9025 and contains specifications for the controller. Figure 1. cRIO-9025 Front Panel 1. LEDs 6. Reset Button 2.
IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. 2 | ni.com | NI cRIO-9025 User Manual and Specifications...
Page 4
Using a Phillips #2 screwdriver, tighten the two captive screws on the front of the cRIO-9025 to 1.3 N · m (11.5 lb · in.) of torque. Dimensions The following figure shows the cRIO-9025 dimensions. 4 | ni.com | NI cRIO-9025 User Manual and Specifications...
Do not tighten or loosen the terminal screws on the power connector while the cRIO-9025 is powered on. Connect the primary power supply and optional secondary power supply to the power connector, as shown in the following figure. 6 | ni.com | NI cRIO-9025 User Manual and Specifications...
Use the Serial VIs to read from and write to the serial port. For more information about the Serial VIs, refer to the LabVIEW Help. Figure 6. Serial Port Pinout 8 | ni.com | NI cRIO-9025 User Manual and Specifications...
Disables console out. Keep this switch in the OFF position during normal operation. IP RESET Switch The following table describes the ON and OFF states of the IP RESET switch. 10 | ni.com | NI cRIO-9025 User Manual and Specifications...
The cRIO-9025 is in safe mode. The software has crashed twice pauses without rebooting or cycling power between crashes. Continuous blinks or The cRIO-9025 has detected an unrecoverable error. Please solid contact NI. 12 | ni.com | NI cRIO-9025 User Manual and Specifications...
512 MB Note For information about the life span of the nonvolatile memory and about best practices for using nonvolatile memory, go to and enter the Info ni.com/info Code SSDBP 14 | ni.com | NI cRIO-9025 User Manual and Specifications...
30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations Safety Voltages Connect only voltages that are within these limits. V-to-C 35 V maximum, Measurement Category 1 16 | ni.com | NI cRIO-9025 User Manual and Specifications...
National Instruments 符合中国电子信息产品中限制使用某些有害物 中国客户 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 。(For information about China RoHS ni.com/environment/rohs_china compliance, go to ni.com/environment/rohs_china Ethernet Cabling The following table shows the standard Ethernet cable wiring connections. 18 | ni.com | NI cRIO-9025 User Manual and Specifications...