USER MANUAL AND SPECIFICATIONS
NI cRIO-9025
Intelligent Real-Time Embedded Controller for CompactRIO
This document describes how to set up and use the NI cRIO-9025 and contains specifications
for the controller.
9
8
7
6
5
1. LEDs
2. Power Connector
3. RS-232 Serial Port
4. USB Port
5. USB Retention Standoff
Refer to the reconfigurable chassis documentation on
about the chassis. Refer to
is set up and configured. For information about software support, visit
the Info Code
swsupport
Figure 1. cRIO-9025 Front Panel
1
ni.com/gettingstarted
.
2
6. Reset Button
7. DIP Switches
8. RJ-45 Ethernet Port 1
9. RJ-45 Ethernet Port 2
ni.com/manuals
for information about using the system after it
3
4
for more information
ni.com/info
and enter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NI cRIO-9025 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments NI cRIO-9025

  • Page 1 USER MANUAL AND SPECIFICATIONS NI cRIO-9025 Intelligent Real-Time Embedded Controller for CompactRIO This document describes how to set up and use the NI cRIO-9025 and contains specifications for the controller. Figure 1. cRIO-9025 Front Panel 1. LEDs 6. Reset Button 2.
  • Page 2: Safety Guidelines For Hazardous Locations

    IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. 2 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 3: Electromagnetic Compatibility Guidelines

    Complete the following steps to install the cRIO-9025 on the chassis. Make sure that no power is connected to the cRIO-9025 or the chassis. Align the cRIO-9025 with the chassis as shown in the following figure. NI cRIO-9025 User Manual and Specifications | © National Instruments | 3...
  • Page 4 Using a Phillips #2 screwdriver, tighten the two captive screws on the front of the cRIO-9025 to 1.3 N · m (11.5 lb · in.) of torque. Dimensions The following figure shows the cRIO-9025 dimensions. 4 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 5 Ethernet, NI recommends using a CAT-5 or better shielded twisted-pair Ethernet cable. Related Information Configuring IP Settings and Installing Software on the cRIO-9025 on page 7 Ethernet Cabling on page 18 NI cRIO-9025 User Manual and Specifications | © National Instruments | 5...
  • Page 6: Ethernet Port

    Do not tighten or loosen the terminal screws on the power connector while the cRIO-9025 is powered on. Connect the primary power supply and optional secondary power supply to the power connector, as shown in the following figure. 6 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 7 If the cRIO-9025 is on a different subnet from the host computer, it does not initially appear under Remote Systems. Use the CONSOLE OUT switch to read the IP address of the cRIO-9025, and add it to Remote Systems in MAX. NI cRIO-9025 User Manual and Specifications | © National Instruments | 7...
  • Page 8: Rs-232 Serial Port

    Use the Serial VIs to read from and write to the serial port. For more information about the Serial VIs, refer to the LabVIEW Help. Figure 6. Serial Port Pinout 8 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 9: Internal Real-Time Clock

    Figure 7. Controller DIP Switches SAFE MODE CONSOLE OUT IP RESET NO APP USER1 SAFE MODE Switch The following table describes the ON and OFF states of the SAFE MODE switch. NI cRIO-9025 User Manual and Specifications | © National Instruments | 9...
  • Page 10: Console Out Switch

    Disables console out. Keep this switch in the OFF position during normal operation. IP RESET Switch The following table describes the ON and OFF states of the IP RESET switch. 10 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 11: User1 Switch

    RT Read Switch VI, refer to the LabVIEW Help. RESET Button Press the RESET button to reset the processor in the same manner as cycling power. LEDs The cRIO-9025 provides the following LEDs. NI cRIO-9025 User Manual and Specifications | © National Instruments | 11...
  • Page 12: Power Led Indicators

    The cRIO-9025 is in safe mode. The software has crashed twice pauses without rebooting or cycling power between crashes. Continuous blinks or The cRIO-9025 has detected an unrecoverable error. Please solid contact NI. 12 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 13 If the cRIO-9025 is restored to the factory network settings, the LabVIEW run-time engine does not load. You must reconfigure the network settings and restart the cRIO-9025 for the LabVIEW run-time engine to load. NI cRIO-9025 User Manual and Specifications | © National Instruments | 13...
  • Page 14: Specifications

    512 MB Note For information about the life span of the nonvolatile memory and about best practices for using nonvolatile memory, go to and enter the Info ni.com/info Code SSDBP 14 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 15: Power Requirements

    Torque for screw terminals 0.2 N · m to 0.25 N · m (1.8 lb · in. to 2.2 lb · in.) Wires per screw terminal One wire per screw terminal NI cRIO-9025 User Manual and Specifications | © National Instruments | 15...
  • Page 16: Shock And Vibration

    30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations Safety Voltages Connect only voltages that are within these limits. V-to-C 35 V maximum, Measurement Category 1 16 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 17: Safety And Hazardous Locations Standards

    For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note For EMC compliance, operate this product according to the documentation. NI cRIO-9025 User Manual and Specifications | © National Instruments | 17...
  • Page 18: Online Product Certification

    National Instruments 符合中国电子信息产品中限制使用某些有害物 中国客户 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 。(For information about China RoHS ni.com/environment/rohs_china compliance, go to ni.com/environment/rohs_china Ethernet Cabling The following table shows the standard Ethernet cable wiring connections. 18 | ni.com | NI cRIO-9025 User Manual and Specifications...
  • Page 19: Worldwide Support And Services

    NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your National Instruments product. Product registration facilitates technical support and ensures that you receive important information updates from NI cRIO-9025 User Manual and Specifications | © National Instruments | 19...
  • Page 20 National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support...