W&H MULTIDEM C27 Instructions For Use Manual
Hide thumbs Also See for MULTIDEM C27:

Advertisement

Instructions for use
Multidem - ENG - Rev 07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTIDEM C27 and is the answer not in the manual?

Questions and answers

Summary of Contents for W&H MULTIDEM C27

  • Page 1 Instructions for use Multidem - ENG - Rev 07...
  • Page 2: Table Of Contents

    Table of contents W&H symbols ....................1 Definition of Terms .
  • Page 3: W&H Symbols

    W&H symbols Symbols displayed on the product and/or used in this manual: WARNING! CAUTION! General comments, (in the event of risk of injury to persons) (in the event of risk of damage to property) with no risk to persons or property Symbols on the device: Not drinking water Observe the instructions for use...
  • Page 4: Definition Of Terms

    1. Definition of Terms...
  • Page 5: General Information

    2. General Information Function and Application Multidem is a pressurized system connected to the water installation that completely demineralizes drinking water for individual customer applications. By reliably locking the filter cartridge in the filter head and controlling the water flow, the innovative locking handle ensures simple and reliable operation. The quality of the filter system has been inspected and confirmed by independent institutes.
  • Page 6 General Information Guarantee Provisions The Multidem filter system is subject to the statutory guarantee of 1 years. A guarantee claim may be asserted only if all instructions in this Handbook are followed and observed. Storage/Transport Adhere to the ambient conditions in the Technical Data (Chapter 9) for storage and transport. The instructions for use should be seen as part of the product and kept for the entire service life of the filter system, and also passed on to subsequent owners.
  • Page 7: Operating And Safety Instructions

    3. Operating and Safety Instructions Qualified personnel Installation and maintenance of the filter system may be carried out only by trained and authorized personnel. Correct Use Perfect and safe operation of the product is subject to the installation, use and maintenance outlined in this document. Only use filter cartridges designed for this filter system.
  • Page 8 Operating and Safety Instructions W&H recommends that the filter system not be decommissioned for a long period of time. Following stagnation times of over a week, the filter should be flushed in accordance with the table below using at least the flushing volumes specified. Following stagnation times of over four weeks, the filter should be replaced.
  • Page 9 Operating and Safety Instructions Filter cartridge production code, e.g. B1252310475 Production year, here: 2011 Production week, here: calendar week 25 Production day from Monday (1) to Friday (5), here: Tuesday Number of the mix variant, here: no. 31 0475 Consecutive number of the filter cartridge, here the 475 cartridge; reset when the day changes Technical Safety Assembly Instructions >...
  • Page 10: Installation

    4. Installation Prior to installation, read the technical data (Chapter 9) and the operating and safety information (Chapter 3). Following storage and transportation below 0 °C, the product must be stored in the open original packaging for at least 24 hours prior to commissioning at the ambient temperatures for operation specified (Chapter 9).
  • Page 11 Installation Inserting the Filter Cartridge Remove the protective cap . Note the next exchange date in the date field on the filter cartridge . Insert the filter cartridge  vertically into the filter head . The filter cartridge can only be inserted when the locking handle is open. Make sure that the filter cartridge is positioned correctly.
  • Page 12 Installation Commissioning Open the water intake and switch on the power supply to the terminal device. Operate the flush valve  and flush the filter system until the filtered water runs clear and without bubbles. At least two bed volumes must be flushed (Chapter 9). Ensure the filter system is aligned vertically during operation! When bleeding/flushing, catch any water leaking from the flush hose ...
  • Page 13: Changing The Filter Cartridge

    5. Changing the Filter Cartridge The Multidem filter cartridge must be replaced when depleted. In the event that the maximum permissible conductivities are reached in the filtrate, always refer to information from the manufacturer of the relevant downstream machine or system. For small sterilizers in accordance with EN 13060, we recommend changing the filter cartridge from a conductivity of 15–20 μS/cm.
  • Page 14: Capacity Tables

    6. Capacity Tables Multidem C27 Conductivity in the intake water in μS/cm Filter capacity in litres 2250 1130 The stated capacities have been tested and calculated on the basis of common application and machine conditions. External factors (e.g. varying crude...
  • Page 15: Repair

    7. Repair > Regularly check the filter system for leaks. > Regularly check the hoses for kinks. Kinked hoses must be replaced. The complete filter system must be replaced in rotation after 10 years. The non-return valve supplied must be replaced every 5 years. Before replacing, read the technical data (Chapter 9) and the operating and safety information (Chapter 3).
  • Page 16: Troubleshooting

    8. Troubleshooting No water flow Cause: Water intake closed. Troubleshooting: Open the water intake at the upstream stop valve or close the locking handle  on the filter head . Cause: Non-return valve was fitted on the outlet side. Troubleshooting: Please fit the non-return valve on the inlet side.
  • Page 17: Technical Data

    9. Technical data Multidem C27 Operating pressure 2 bar to max. 8.6 bar Water inlet temperature 4 °C to 40 °C Ambient temperature during operation 4 °C to 30 °C storage -20 °C to 50 °C Nominal flow 60 l/h Pressure loss at nominal flow 0.2 bar...
  • Page 18: Order Numbers

    10. Order Numbers A812016X A812018X Multidem C27 Spray gun set filter cartridge A800502X Primo 5...
  • Page 19 Order Numbers 19723110 A812020X A812019X Connection kit 2 sterilizer 3m - 6x4 mm PTFE tubing A812005X A812105X A812106X Water block safety valve Spiral tubing Water gun...
  • Page 20 Order Numbers A812022X A812021X 3/8” Non-return valve Adaptors 6 to 8 mm tubings...
  • Page 21: Disposal Of Used Filter Cartridges

    Disposal of used filter cartridges The used cartridges are classified as special, non hazardous waste. The CER number for used ion-exchange resins used for the production of demineralized water is: 19 09 05. The products must be disposed in accordance with current local, regional and country regulations.
  • Page 22 Notes...
  • Page 23 Authorized W&H service partners Find your nearest W&H service partner at http://wh.com - http://med.wh.com Simply go to the menu option »Service« for full details. Alternatively please contact: W&H UK LIMITED, 6 Stroud Wood Business Centre, Park Street, St.Albans, Herts AL2 2NJ t +44 1727 874990 f +44 1727 874628 technical.uk@wh.com...
  • Page 24 Manufacturer Multidem ENG Instructions for Use - Rev 07 W&H Sterilization S.r.l. Italy, I-24060 Brusaporto (Bg), via Bolgara, 2 t +39/035/66 63 000 f +39/035/50 96 988 wh.com Subject to alterations med.wh.com 21/11/2019 vet.wh.com...